Technical data
888-282-2123 • www.jokabsafetyna.com
ABB JOKAB SAFETY
Tina 10B Tina 10C Tina 10A
4:34
Tina 10A/B/C
Adaptation Unit
Tina 10 A/B/C are three connection
units with M12 connections, that make
it easy to connect a light curtain or light beam
Focus with OSSD outputs to the dynamic safety
circuits of Vital and Pluto. This also enables complete
external interconnections, with M12 cabling, which
reduces the cabling to and connections in the appara-
tus enclosure. Tina 10 A/B/C has LEDs for function
indication, with green, red or ashing green/red
indications.
Tina 10A has two M12 connections that are
connected to: 1) Vital/Pluto and 2) a light curtain/light
beam Focus receiver. See the Connection Example
HR7000L-01
on page 6:36
.
Tina 10B has three M12 connections that are
connected to: 1) Vital/Pluto and 2) a light curtain/light
beam Focus receiver, and 4: An external reset button
and muting lamp, such as unit FMI-1C. See the
Connection Examples HR7000L-01
on page 6:36
.
Tina 10C has three M12 connections that are
connected to: 1) Vital/Pluto and 2) a light curtain/light
beam Focus receiver, and 4: a light curtain/light beam
Focus Transmitter. See the Connection Examples
HH3302D
on page 4:49
, HR7000L-01
on page 6:36
.
Application
■ Adaptation of safety sensors with
OSSD outputs to the dynamic
safety circuit. For example: Focus
light curtain/light beam
Features
■ Simplies the system as well as
maintaining the safety level
■ Indication of status by LED
Approvals
TÜV Nord
Tina 10A, 10B and 10C Connnections
1
1 1
3
2
3
2