Technical data

888-282-2123 • www.jokabsafetyna.com
ABB JOKAB SAFETY
4:33
Tina 8A
Connection Examples of Safety Sensors to Tina 8A
Connection 1
One Eden is connected directly to the Tina 8A. The
Eden status is shown by an LED on the Adam sensor.
A status information signal is also connected to Tina 8A.
Connection 2
One Focus safety light grid/curtain is connected to
the Tina 8A via a Tina 10A. The output from the Tina
10A is via a M12 connector. The connection between
Tina 10A and Tina 8A is achieved using a cable with
M12 connectors on each end.
The Tina 10A has two LEDs which show the status
of the light grid. The same status information signal
is connected to the Tina 8A. Tina10A and the Focus
transmitter are connected to Tina 8A via an M12-3B.
Connection 3
A Spot 10 light beam is connected directly to Tina 8A.
A ‘Y’ connector M12-3B for M12 plugs is connected
to the transmitter and the receiver. The status informa-
tion shown on the Spot LED is also connected to Tina
8A.
Connection 4
A safety mat is connected via a Tina 6 A to the Tina
8A. (A safety strip or safety bumper is connected in
the same manner.) Two LEDs in Tina 6A shows the
status of the mat. The same status information signal
is connected to Tina 8A.
Connection 5
One Smile is connected to the Tina 8A. The informa-
tion shown by an LED on the Smile is also connected
to the terminal block on the Tina 8A.
Connection 6
A safety interlock switch is connected via a Tina 3A
mounted directly on the switch. The output from the
Tina 3A is via a M12 connector. The connection between
the Tina 3A and the Tina 8A is therefore simply made
with a cable with M12 connectors on each end. On
the Tina 3A there is a LED which shows the status of
the switch. The same information signal is connected
to the Tina 8A.
Connection 7
A Spot 35, transmitter and receiver are connected
directly to to the Tina 8A via a M12-3B ’Y’ connector.
The status information shown by the LED on the Spot
is also connected to the Tina 8A.
Connection 8
Tina 1A is a plug which has to be connected to Tina 8A
inputs when no sensor is required, in order to complete
the safety connection circuit.
Note: All input connectors on
the Tina 4A/8A must be connected
to sensors or have Tina 1A plugs fitted.
Tina 4A
Vital Safety
Controller