Technical data

888-282-2123 • www.jokabsafetyna.com
ABB JOKAB SAFETY
4:30
Tina 6A
Adaptation Unit
Tina 6A monitors short circuits. It is used to adapt the
safety sensors with safety contact strips and safety
mats with relay outputs to the dynamic safety circuit.
The device is tted with a LED for status indication of
the dynamic safety circuit.
Application
Short circuit monitoring and adaptation
of safety sensors to the dynamic safety
circuit
For example: contact edges, bumpers and
safety mats
Features
Simplies the system as well as
maintaining the safety level
Indication of status by LED
Approvals
Manufacturer
ABB AB/Jokab Safety, Sweden
Ordering Information
see page 4:58
Level of safety
IEC/EN 61508-1…7
EN 62061
EN ISO 13849-1
EN 954-1
SIL3
SIL3
PL e, category 4
Category 4
PFH
d
4.50×10
-9
Power supply
Operating voltage
Total current consumption
Current through
safety device contacts
Short circuit
current between contacts
Time delay t (in/out)
Voltage supply at normal
operation (protection OK) and
24 VDC supply voltage
24 VDC + +15%, -25%
47 mA (57 mA with
max information output)
Information output: Max 10 mA
12 mA
10 mA
t < 70 µs
Dynamic input: between
9 and 13 volt (RMS)
Dynamic output: between
9 and 13 volt (RMS)
Information output: ~ 23 VDC
Protection class
IP67
Ambient temperature
Storage: -30…+70°C
Operation: -10…+55°C
Humidity range
35 to 85 %
(with no icing or condensation)
Housing material
Based on polyamide,
Macromelt OM646 (V0)
Connectors
M12 5-pole male
M12 5-pole female
Size
63 × 31 × 15 (L × W × H)
Weight
~30 g
Color
Black
Approved standards
European Machinery Directive
2006/42/EC
EN ISO 12100-1:2003
EN ISO 12100-2:2003
EN 60204-1:2007
EN 954-1:1996
EN ISO 13849-1:2008
EN 62061:2005
Certificates V Nord
33
62.2
3311. 2
M12 M12
LED
× 2
1
2
3
4
5
1
2
3
4
5
5-pin M12 male contact
+24 VDC
Dynamic input signal
0 VDC
Dynamic output signal
Information
5-pin M12 female contact
Safety circuit A1-A2
Safety circuit A1-A2
Safety circuit B1-B2
Safety circuit B1-B2
Not used
TÜV Nord
Tina 6A Technical Data