Technical data

888-282-2123 • www.jokabsafetyna.com
ABB JOKAB SAFETY
4:23
Tina is available in several versions depending on
the type of safety component that is connected to the
Vital or Pluto circuit. Also available is a bypassing unit,
three connector blocks with 2, 4 or 8 M12 connectors,
and a blind plug for un-used connections.
As an accessory there is a Y-connector for series
or parallel connection and even for connection of light
beams with separate transmitter and receiver. Tina
units are also included in emergency stop models
Smile Tina and Inca Tina. This is to adapt ABB
Jokab Safety's products to dynamic safety circuits.
All Tina-units are designed to decode the dynamic
signal in the safety circuit of Vital/Pluto.
1
Tina 2A/B, Tina 3A and Tina 7A are used to
connect safety components with mechanical con-
tacts, such as emergency stops, switches and light
curtains or light beams with relay outputs.
Note: In order to maintain safety category 4 and to reduce
the risk of electrical interference, Tina 2 A, 3A and 7A units
must be installed within the same physical encapsulation
as the safety component that is to be monitored, and this
is to be connected to the Tina unit with as short a cable
as possible.
Tina 10A/B/C
units are used for connection of Focus
light beams/curtains to Vital or Pluto. Tina 10B has
an extra M12 connector that enables reset, a reset lamp
and switching of the Focus supply voltage. The Tina
10C has an additional M12 connector that permits
a Focus transmitter to receive power.
2
Tina 6A is used to connect door sensitive edges
and safety mats, and provides an indication for
each unit. (Tina 7A may also be used.) If a Tina 6A is
connected close to the edge or mat, the risk of elec-
trical interference is reduced.
3
Tina 4A, Tina 8A, Tina 11A and Tina 12A
are used as terminal blocks and simplify con-
nection to a Vital or Pluto safety circuit. Each safety
component is connected to the terminal block via
an M12 connection. A terminal block is connected
to the apparatus enclosure by means of a cable that
also contains status information from each safety
com-ponent that is connected to Tina 4A/Tina 8A and
summed information from Tina 11A/Tina 12A. Tina
1A must be used as a blanking plug in unused M12
connections.
4
Tina 5A is used to bypass the safety sensors
in Vital security loop and for monitoring the indi-
cator light switch off. Tina 5A bypass units are used
for bypassing of safety sensors in a dynamic circuit
and provides the possibility for supervision of bypass
lamp indication.
Available in Several Variations
1
Tina 2A Tina 2B Tina 3A
Tina 7A Tina 10A Tina 10B/C
Tina 6A
2
3
Tina 4A
Tina 1A
Tina 8A
Tina 11A Tina 12A
4
Tina 5A
Why should you choose Tina?
Safety circuit,PL e, EN ISO 13849-1
Individual status indication of every connected
unit in the safety circuit
Supervision of lamp indicating bypassing
of safety device
Quick release M12 connector