Technical data
5/35 2TLC172001C0202 | ABB Safety Handbook
5
Terminal block
Tina 11A
Description
Tina 11A is a connection block with two 5-pin M12 connec-
tions. It is used to connect two safety sensors with M12 con-
tacts via a single cable to a controller or PLC. This simplifies
cable running and reduces cable costs. Multiple connection
blocks can be connected to a Vital/Pluto.
Technical data – Tina 11A
Article number 2TLA020054R1700
Level of safety
IEC/EN61508-1…7 SIL3
EN62061 SIL3
ENISO13849-1 PLe/Cat. 4
PFH
D
4.50 × 10
-9
Power supply
Operating voltage 24 VDC + +15%, -15%
Total current consumption 17 mA (27 mA with max information
output)
Information output: Max 10 mA
Time delay t (in/out) t < 60 µs
Voltage supply at normal opera-
tion (protection OK) and 24 VDC
supply voltage
Dynamic input: between 9 and 13 volt
(RMS)
Dynamic output: between 9 and 13
volt (RMS)
Information output: ~ 23 VDC
Protection class IP67
Ambient temperature Storage: -30…+70°C
Operation: -10…+55°C
Humidity range 35 to 85 % (with no icing or conden-
sation)
Housing material Based on polyamide, Macromelt
OM646 (V0)
Connectors Out: M12 5-pole male (nr 2)
In: M12 5-pole female (nr 1,3)
Size 74 × 36 × 11mm (L × W × H)
Weight ~40 g
Colour Black
Approved standards European Machinery Directive
2006/42/EC
ENISO12100-1:2003, ENISO12100-
2:2003,
EN60204-1:2007,
ENISO13849-1:2008,
EN62061:2005
Certificates TÜV Nord
11, 2
13, 4
46, 5
77
36
1
2
3
4
5
5
2
4
3
1
5
2
4
3
1
5-pin M12 male connector
(contact #1):
1. +24 VDC
2. Dynamic input signal
3. 0 VDC
4. Dynamic output signal
5. Summarized information
(contact #2-3)
5-pin M12 female connector
(contact #2-3)
1. +24 VDC
2. Dynamic input signal
3. 0 VDC
4. Dynamic output signal
5. Information
Approvals:
Application:
– Terminal block for connection
of two safety sensors with
5-pin M12 connectors and
adaptation to the dynamic
safety circuit.
Features:
– Simplifies cable routing and
reduces cable costs.
– Allows connection of two
safety sensors to the dynamic
safety circuit.
TÜV
NORD