Technical data

ABB Safety Handbook | 2TLC172001C0202 5/34
5
Tina 10A, 10B and 10C connections
1
1 1
3
2
3
2
Tina 10B Tina 10C Tina 10A
13,4
11,2
36
77
4,5
46,5
36
77
46,511,2
13,4
36
77
46,511,2
13,4
Technical data – Tina 10A/B/C
Article number
Tina 10A
Tina 10B
Tina 10C
2TLA020054R1200
2TLA020054R1300
2TLA020054R1600
Level of safety
IEC/EN61508-17 SIL3
EN62061 SIL3
ENISO13849-1 PLe/Cat.4
PFH
D
4.50 × 10
-9
Power supply
Operating voltage 24 VDC + +20%, -20%
Total current consumption 60mA (70mA with max. info signal out)
Info signal out: Max. 10 mA
Time delay t (in/out) t < 120 µs
Voltage supply at normal opera-
tion (protection OK) and 24 VDC
supply voltage
Dynamic input signal: 9 to 13 V (RMS)
Dynamic output signal: 9 to 13V
(RMS)
Info signal out: ~23 VDC
Protection class IP67
Ambient temperature Storage: –10+55°C
Operation: –10+55°C
Humidity range 35 to 85% (without icing or condesa-
tion)
Housing material Based on polyamide, Macromelt
OM646 (V0)
Size 74 × 36 × 11mm (L × W × H)
Weight ~40 g
Colour Black
Number of units connected to
Vital1
Max. number of Tina 10A:
Max. number of Tina 10B/C:
6
4 when Focus is supplied by Vital and
a reset lamp is used
6 when Focus is supplied separately
or no reset lamp is used
Number of units connected to
Pluto, Vital 2 or 3, per input
Max. number of Tina 10A/B/C:
2
Connectors
Tina 10A
Tina 10B
Tina 10C
1: for Vital or Pluto
2: for Focus receiver
1: for Vital or Pluto
2: for Focus receiver
3: for Reset unit
1: for Vital or Pluto
2: for Focus receiver
3: for Focus transmitter
Approved standards European Machinery Directive
2006/42/EC
ENISO12100-1:2003,
ENISO12100-2:2003,
EN60204-1:2007,
ENISO13849-1:2008,
EN62061:2005, EN61496-1:2004 +
A1:2008
Certificates TÜV Nord