Technical data
5/31 2TLC172001C0202 | ABB Safety Handbook
5
1
2
3
4
5
6
12
13
Shield
Connection block
Tina 8A
Tina 8A is a connection block with eight 5-pin M12 connec-
tions. It is used to connect multiple safety sensors with M12
contacts via a single cable to a controller or PLC. This simpli-
fies cable running and reduces cable costs. Multiple connec-
tion blocks can be connected to a Vital/Pluto. Tina 1A is used
for unused M12 connections.
Technical data – Tina 8A
Article number 2TLA020054R0500
Level of safety
IEC/EN61508-1…7 SIL3
EN62061 SIL3
ENISO13849-1 PLe/Cat. 4
PFH
D
4.50 × 10
-9
Power supply
Operating voltage 24 VDC + +15%, -15%
Total current consumption 15 mA (25 mA with max information
summary output)
Information output: Max 10 mA
Time delay t (in/out) t < 60 µs
Voltage supply at normal opera-
tion (protection OK) and 24 VDC
supply voltage
Dynamic input: between 9 and 13 volt
(RMS)
Dynamic output: between 9 and 13
volt (RMS)
Information output: ~ 23 VDC
Protection class IP67
Ambient temperature Storage: -30…+70°C
Operation: -10…+55°C
Humidity range 35 to 85 % (with no icing or conden-
sation)
Housing material Based on polyamide, Macromelt
OM646 (V0)
Connectors M12 5-pole female (8x)
13-pin connection block
Size 149 × 50 × 43 (L × W × H)
Weight ~140 g
Colour Black
Approved standards European Machinery Directive
2006/42/EC, ENISO12100-1:2003,
ENISO12100-2:2003, EN60204-
1:2007, ENISO13849-1:2008,
EN62061:2005
Certificates TÜV Nord
5-pin M12 female contact (x8):
1. +24 VDC
2. Dynamic input signal
3. 0 VDC
4. Dynamic output signal
5. Information
Connection block:
1. +24 VDC
2. Dynamic input signal
3. 0 VDC
4. Dynamic output signal
Cable shield
5. Information (contact #1)
6. Information (contact #2)
7. Information (contact #3)
8. Information (contact #4)
9. Information (contact #5)
10. Information (contact #6)
11. Information (contact #7)
12. Information (contact #8)
13. Summarized information (contact #1-8)
Approvals:
Application:
– Connection block for up to
eight safety sensors adapted
to the dynamic safety circuit.
Features:
– Simplifies cable routing and
reduces cable costs.
– Allows branching of up to four
safety sensors to the dynamic
safety circuit.
TÜV