Technical data

ABB Safety Handbook | 2TLC172001C0202 5/30
5
Adaptation unit
Tina 7A
Description
Tina 7A is a device that adapts the safety sensors with
mechanical positive forced disconnecting contacts, such as
emergency stops, switches and light curtains/light grids with
their own relay outputs to the dynamic safety circuit.
The device is designed for installation in an equipment
cabinet where it can be mounted directly on a 35 mm DIN
busbar, and the conductors are then connected directly to
the screw terminals.
Technical data – Tina 7A
Article number 2TLA020054R0700
Level of safety
IEC/EN61508-17 SIL3
EN62061 SIL3
ENISO13849-1 PLe/Cat. 4
PFH
D
4.50 × 10
-9
Power supply
Operating voltage 24 VDC + +15%, -25%
Total current consumption 47 mA (57 mA with max information
output) Information output: Max 10 mA
Current through safety device
contacts 12mA
Short circuit current between
contacts 10mA
Time delay t (in/out) t < 70 µs
Voltage supply at normal opera-
tion (protection OK) and 24 VDC
supply voltage
Dynamic input: between 9 and 13 volt
(RMS)
Dynamic output: between 9 and 13
volt (RMS) Information output: ~ 23
VDC
Protection class IP20
Ambient temperature Storage: -30…+70°C
Operation: -10…+55°C
Humidity range 35 to 85 % (with no icing or conden-
sation)
Housing material Based on polyamide, Macromelt
OM646 (V0)
Connectors 5-pin connection block (power sup-
ply, dynamic in/out, info)
4-pin connection block (safety loop
A1-A2, B1-B2)
Mounting DIN rail
Size 61 × 46 × 14 (L × W × H)
Weight ~35 g
Colour Black
Approved standards European Machinery Directive
2006/42/EC, ENISO12100-1:2003,
ENISO12100-2:2003, EN60204-
1:2007, ENISO13849-1:2008,
EN62061:2005
Certificates TÜV Nord
13
62
45, 7
35, 5
2
4
3
1
5
6
7
8
9
Connection block:
1. +24 VDC
2. Dynamic input signal
3. 0 VDC
4. Dynamic output signal
5. Information
6. Safety circuit A1-A2
7. Safety circuit A1-A2
8. Safety circuit B1-B2
9. Safety circuit B1-B2
Approvals:
Application:
Adaptation of safety sensors
with mechanical contacts to
the dynamic safety circuit.
For example:
Emergency stops
Switches
Light beams / light curtains
with relay outputs
Features:
Simplifies the system as well
as maintaining the safety level
Indication of status by LED
Adapted for easy installation
on 35 mm DIN rail in cabinets
TÜV
NORD