Technical data

5/17 2TLC172001C0202 | ABB Safety Handbook
5
Vital 3 is a safety controller that combines functionality with the quick and easy
installation of safety sensors. With two safe input functions and two different output
groups, Vital 3 offers the capability to exclusively control smaller machine safety sys-
tems that would otherwise have required a programmable controller or multiple safety
relays. How the two output groups are controlled by the input functions depends on
which of the three operating modes is selected (see Selection of operating mode).
Input function 1
A two-channel safety circuit designed for opening contacts, e.g. two-channel emer-
gency stop or ABB JokabSafety's safety switch JSNY5. One channel is fed with the
dynamic signal and the other with static +24 VDC.
Input function 2
A dynamic safety circuit where ABB JokabSafety's safety sensors Eden, Tina and
Spot can easily be connected in series. Up to 12 Eden or Tina devices can be con-
nected in series per input function.
Output group 1
A safe relay output in a duplicated series and a safe transistor output with output
voltage of -24 VDC.
Output group 2
A safe relay output in a duplicated series and a safe transistor output with output
voltage of -24 VDC. In addition, output group 2 contains a non-safe transistor output
with output voltage of +24 VDC, intended for information. The output group can have
time delay from 0 to 1.5 s.
Selection of operating modes
Vital 3 can be configured to operate in one of three operating modes M1, M2 or M3.
The selection of operating modes is done by connecting one of the terminals M1, M2
or M3 to +24 V.
Vital 3