Installation manual

59
Eaton
Eaton
17 Eaton
171 Eaton
Easy Installation Termination Addressing Sensors RS485 Meters RS485 Interface
No
Yes
No
No No RS422
Overview
•
Interface not integrated; Retrofit RS485 interface card.
•
4-pin cable – only on RS485/422 B connection of the Solar-Log™
•
Communication address does not have to be assigned
•
Multi-string technology
Eaton inverters are fitted with 1 or 3 MPP trackers depending on the model. Each string input is moni-
tored separately and ideally adjusted to the connected modules.
The Solar-Log™ automatically detects how many inverters and strings are active during inverter de-
tection.
Note
The order in which the inverters are displayed in the Solar-Log™ after detection is random.
We strongly recommend that you change the order of the inverters immediately after de-
tection at startup, in the Configuration/Basis/Inverters dialog box.
The inverters can be identified using the displayed serial number.
•
Installation steps
Disconnect the power for the inverter and Solar-Log™
Connect the RS485 interface in the inverter
Connect inverters to the Solar-Log™
Connect the inverters to each other
Installing the RS485 interface
Procedure
Insert the RS485 interface in the bottom of the inverter in accordance with the interface card
installation instructions and screw in.
Connect inverters to the Solar-Log™
The wiring is done using a
•
ready-made data cable (optional extra; not supplied)
or
•
self-made, shielded 4 wire data cable and terminal block connector.