Component Guide
Platt #
Part Number
Thermal
Magnetic
Breaker
Size
NEMA
Size
NEMA
Rating
Control
Voltage
Starter/
Overload
Voltage
Overload
Class
Overload
Range
708269 K1BP-2E11J6 15A 0 3R 110V 60Hz 208-480V 10/20/30 5.7 - 18.9A
708407 L1BP-2E13J6 25A 1 3R 110V 60Hz 208-480V 10/20/30 9 - 30A
708409 M1BP-2E18J6 60A 2 3R 110V 60Hz 208-480V 10/20/30 27 - 80A
708412 N1BP-2E1CJ6 100A 3 3R 110V 60Hz 208-480V 10/20/30 27 - 80A
708415 P1BP-2E2GJ6 200A 4 3R 110V 60Hz 208-480V 10/20/30 65 - 200A
708419 Q1BP-2E3MJ6 400A 5 3R 110V 60Hz 208-480V 10/20/30 105 - 320A
708269 K1BP-2E11J6 50VA
708407 L1BP-2E13J6 50VA
708409 M1BP-2E18J6 50VA
708412 N1BP-2E1CJ6 50VA
708415 P1BP-2E2GJ6 150VA
708419 Q1BP-2E3MJ6 250VA
Littelfuse
Part #
Platt
Part #
Littelfuse
Part #
Platt
Part #
Littelfuse
Part #
Platt
Part #
Littelfuse
Part #
Platt
Part #
754924 X4050PSF1 50VA FLM.600 032893 KLDR001 033176 KLDR001 033176 KLDR.500 033171
483486 X4150PSF1 150VA FLM002 032903 KLDR03.5 161642 KLDR003 033180 KLDR01.5 088335
470181 X4250PSF1 250VA FLM03.5 032910 KLDR006 164710 KLDR005 033182 KLDR02.5 162314
Platt # Part # Platt # Part # Platt # Part # Platt # Part # Platt # Part #
708269 K1BP-2E11J6 426218 ZA16-34 400817 ZA16-80 667719 CL-523R 401152 ZA16-81 654113 CL-502R
708407 L1BP-2E13J6 431513 ZA40-34 401157 ZA40-80 667719 CL-523R 401156 ZA40-81 654113 CL-502R
708409 M1BP-2E18J6 431517 ZA75-34 401161 ZA75-80 667719 CL-523R 401159 ZA75-81 654113 CL-502R
708412 N1BP-2E1CJ6 431517 ZA75-34 401161 ZA75-80 667719 CL-523R 401159 ZA75-81 654113 CL-502R
708415 P1BP-2E2GJ6 ZA185-34 ZA185-80 667719 CL-523R ZA185-81 654113 CL-502R
708419 Q1BP-2E3MJ6 ZA300-34 ZA300-80 667719 CL-523R ZA300-81 654113 CL-502R
208/240V Indicator
NOTE: The In stock Pump Panels do not
Include a Control Power Transformer
and are wired for 120V Control. Use the
tables below to add a CPT or change coil
voltage.
Part Number
Platt #
Part Number
208V Coil
240V Coil
115V
Secondary Fuse
Size
208V
240V
48 x 24 x 12
24 x 12.5 x 7
48 x 24 x 12
18 x 10 x 7
18 x 10 x 7
24 x 12.5 x 7
Note: You must change Coil & Indicator to change Control voltage from 120V, MAX CONTROL VOLTAGE IS 300V
Panels, Control Transformers, and Replacement Coil/Indicator Lamps
PUMP PANELS
24V AC Coil
24V Indicator RED
110V standard control voltage from separate power source.
For 208 - 480V Input Voltage feed from input feeders as control voltage see specs table and select control voltage
transformer to add to panel.
Control Transformers
480V
Primary Fuse (Select Fuse Based on Voltage) (2 Required)
Replacement Coils & Indicator Lamps
Panel Specification
Platt #
Part Number
Enclosure Size
Controls
VA
Platt #
ABB Pump Panel
Control Transformer
Indicator Lamp
Replacement
Coil
04/16/2013 REV C