Hardware Manual
Table Of Contents
- List of related manuals
- Table of contents
- Safety instructions
- Introduction to the manual
- Overview of the Ethernet network and the FENA-01/-11/- 21 module
- Mechanical installation
- Electrical installation
- Modbus/TCP protocol
- Modbus/TCP – Start-up
- Contents of this chapter
- Warnings
- Drive configuration
- Starting up fieldbus communication for ACS355 drives
- Starting up fieldbus communication for ACSM1 drives
- Starting up fieldbus communication for ACS850 and ACQ810 drives
- Starting up fieldbus communication for ACS880 and ACS580 drives
- Client configuration
- Modbus/TCP – Communication profiles
- Modbus/TCP – Communication protocol
- Modbus/TCP – Diagnostics
- Modbus/TCP – Start-up
- EtherNet/IP protocol
- EtherNet/IP – Start-up
- Contents of this chapter
- Warnings
- Drive configuration
- Starting up fieldbus communication for ACS355 drives
- Starting up fieldbus communication for ACSM1 drives
- Starting up fieldbus communication for ACS850 and ACQ810 drives
- Starting up fieldbus communication for ACS880 and ACS580 drives
- Configuring the client
- EtherNet/IP – Communication profiles
- Contents of this chapter
- Communication profiles
- ODVA AC/DC drive profile
- ODVA output attributes
- ODVA input attributes
- Faulted (Control supervisor object)
- Warning (Control supervisor object)
- Running Forward (Control supervisor object)
- Running Reverse (Control supervisor object)
- Ready (Control supervisor object)
- Ctrl From Net (Control supervisor object)
- Ref From Net (AC/DC drive object)
- At Reference (AC/DC drive object)
- State (Control supervisor object)
- Speed Actual (AC/DC drive object)
- Torque Actual (AC/DC drive object)
- ABB Drives communication profile
- EtherNet/IP – Communication protocol
- Contents of this chapter
- EtherNet/IP
- Object modeling and functional profiles
- Assembly objects
- Basic speed control assembly
- Basic speed control plus drive parameters assembly
- Extended speed control assembly
- Extended speed control plus drive parameters assembly
- Basic speed and torque control assembly
- Basic speed and torque control plus drive parameters assembly
- Extended speed and torque control assembly
- Extended speed and torque control plus drive parameters assembly
- ABB Drives profile with set speed assembly
- ABB Drives profile with set speed plus drive parameters assembly
- ABB Drives profile with set speed and set torque assembly
- ABB Drives profile with set speed and set torque plus drive parameters assembly
- Transparent 16 with one assembly
- Transparent 16 with one assembly plus drive parameters
- Transparent 16 with two assembly
- Transparent 16 with two assembly plus drive parameters
- Transparent 32 with one assembly
- Transparent 32 with one assembly plus drive parameters
- Transparent 32 with two assembly
- Transparent 32 with two assembly plus drive parameters
- Class objects
- Identity object, class 01h
- Motor data object, class 28h
- Control supervisor object, class 29h
- AC/DC-drive object, class 2Ah
- Drive parameter object, class 90h
- Fieldbus configuration object, class 91h
- TCP/IP interface object, class F5h
- Ethernet link object, class F6h
- Connection object, class 05h
- Acknowledge handler object, class 2Bh
- EtherNet/IP – Diagnostics
- EtherNet/IP – Start-up
- PROFINET IO protocol
- PROFINET IO – Start-up
- Contents of this chapter
- Warnings
- Drive configuration
- Starting up fieldbus communication for ACS355 drives
- Starting up fieldbus communication for ACSM1 drives
- Starting up fieldbus communication for ACS850 and ACQ810 drives
- Starting up fieldbus communication for ACS880 and ACS580 drives
- Configuring the master station
- PROFINET IO – Communication profiles
- PROFINET IO – Communication protocol
- Contents of this chapter
- PROFINET IO
- PROFINET IO in FENA
- Cyclic message types
- Parameter handling using acyclic parameter access mechanism (DP-V1)
- Header and frame structures
- DP-V1 read/write request sequence
- Function blocks for sending DP-V1 messages (Siemens S7)
- Parameter data transfer examples
- Example 1a: Reading a drive parameter (array element)
- Example 1b: Reading 3 drive parameters (multi-parameter)
- Example 2a: Writing a drive parameter (one array element)
- Example 2b: Writing 2 drive parameters (multi-parameter)
- Example 3: Reading a PROFIdrive parameter
- Example 4: Configuring the process data written to the drive
- Example 5: Determining the source of the process data read from the drive
- Diagnostic and alarm mechanism
- PROFINET IO – Diagnostics
- PROFINET IO – Start-up
- Technical data
- Appendix A – PROFIdrive parameters and I&M records of PROFINET IO
- Appendix B – ABB IP configuration tool for FENA
- Appendix C – FENA configuration web pages
- Further information
Modbus/TCP – Start-up 57
27 FBA PAR
REFRESH
Validates any changed adapter module
configuration parameter settings. After
refreshing, the value reverts automatically to
0 = Done.
Note: This parameter cannot be changed while
the drive is running.
0 = Done
ACS355/ACSM1:
FBA PAR
REFRESH
ACS850/ACQ810:
FBA par refresh
ACS880/ACS580:
FBA A/B par
refresh
0 = Done Refreshing done
1 = Refresh Refreshing
28 PAR TABLE VER Read-only. Displays the parameter table
revision of the fieldbus adapter module
mapping file stored in the memory of the drive.
In format xyz, where
x = major revision number
y = minor revision number
z = correction number
OR
in format axyz, where
a = major revision number
xy = minor revision numbers
z = correction number or letter.
N/A
ACS355:
FILE CPI FW REV
ACSM1:
PAR TABLE VER
ACS850/ACQ810:
Par table ver
ACS880/ACS580:
FBA A/B par table
ver
Parameter table revision
29 DRIVE TYPE
CODE
Read-only. Displays the drive type code of the
fieldbus adapter module mapping file stored in
the memory of the drive.
N/A
ACS355:
FILE CONFIG ID
ACSM1:
DRIVE TYPE
CODE
ACS850/ACQ810:
Drive type code
ACS880/ACS580:
FBA A/B drive type
code
Drive type code of the fieldbus adapter module
mapping file
No. Name/Value Description Default