Main Catalog Electricity meters for modular enclosures and DIN rail
Introduction DIN rail mounted electricity meters Modular DIN Rail Products offer a wide range of functions to be integrated in electrical installations with significant benefits for the user. DIN rail mounted electricity meters are designed for high level performance and are safe and fast to install. Global business The DIN rail mounted electricity meters are available in five product lines: ODINsingle and DELTAsingle for single phase metering and ODIN, DELTAplus and DELTAmax for three phase metering.
Table of contents Contents: Introduction.................................................................................................................................... 2 Table of contents............................................................................................................................ 3 Applications in commercial buildings.............................................................................................. 4 Industrial applications....................................
Applications in commercial buildings Modern sub-metering increases energy efficiency and saves money by fair and accurate cost distribution. Requirements for a deliberate strategy to manage and control energy consumption are having an increasing impact on commercial buildings such as shopping centers, offices, hotels and airports. Electricity meters in commercial buildings are usually acquired by the property owner and read automatically via a facility or building management system.
Industrial applications ABB meters help industry manage electricity cost distribution and make more effective use of the energy it consumes. ABB electricity meters find many uses in industry, usually in one of three areas; cost distribution, effective use of energy, improved control. One common feature is that they generally interact with a plant’s Energy Management System, which reads the meter and then forwards the result for further handling.
Object metering “To measure is to know” Long list of domestic objects Electric bills keep getting bigger and bigger, and increased consumption probably plays a bigger part than higher prices. At home and at work, energy-hungry items like computers, terminals, servers, climate-control equipment and intense lighting all push up costs. One of the simplest ways to save money and energy is to make electricity consumption more visible – via object metering.
Joint residential sourcing Direct and indirect savings plus a boost for the environment Unlike applications where a separate billing meter is installed in every apartment or residence for individual billing, joint residential sourcing involves having one central ‘billing’ meter. The housing association, condominium or equivalent then acts as a single electricity subscriber and redistributes its costs amongst its members according to their actual consumption.
Billing applications ABB meters meet key regulatory and practical demands for billing applications. Billing employs electricity meters to measure consumption and use this reading to generate an invoice, usually monthly, paid by the user to the energy supplier for the electricity consumed. For this reason, it is also known as revenue metering. Those who pay bills, usually home-owners or businesses, naturally only want to pay for the electricity they use.
Communication Communication is getting more important every day. Computers and telecommunications drive the development of both technology and infrastructure for communication. Communication is widely used in modern metering applications. Open standards Open standards are important to communication. Through open standards, equipment from various suppliers can work together and safe solutions be implemented.
Selection table Network Type Max current Direct Connection Max current CTVT Connection Voltage Active energy Reactive engergy Single phase + N 65 - 1 x 220-240 V Yes No Single phase + N 65 - 1 x 220-240 V Yes No Single phase + N 80 - 1 x 220-240 V Yes No Single phase + N 80 - 1 x 220-240 V Yes No Single phase + N 80 - 1 x 220-240 V Yes No Single phase + N 80 - 1 x 220-240 V Yes No ODINsingle DELTAsingle ODIN 3 phase + N 65 - 3 x 230/400 V Yes No 3 phase + N
Built in comm. Internal Clock Instrument Values Accuracy Class IR No No Class B (Cl. 1) IR No No IR No IR IR Pulse output Type - No OD1065 14 Class B (Cl. 1) - Yes OD1365 14 No Class B (Cl. 1) - Yes FBB 11200 18 Yes * No Class B (Cl. 1) 2 Yes FBB 11205 18 Yes * No Class B (Cl. 1) 4 Yes FBB 11206 18 IR No No Class B (Cl. 1) - No FBU 11200 18 IR No No Class A (Cl. 2) - Yes OD4110 22 IR No No Class A (Cl.
ODINsingle Product brief 12 Electricity meters | 2CMC480022C0003 Key applications Communication • Applications in Commercial buildings • Pulse output • Application in Industry • • Object metering IR port for Serial Communication Adapter Meter performance Installation • Single phase • 2 DIN modules width • Direct connected up to 65 A • Wide temperature range • Active energy • Accuracy class B (Cl .
ODINsingle Description The ODINsingle is a compact meter for installation in single phase networks. The meter is mounted on a DIN rail and is suitable for installation in distribution boards and small enclosures such as consumer units. The meter is available in two versions, one with pulse output and resettable register and one without. Both these versions measures active energy. The product is configuration free which makes it very easy to deal with in all applications.
ODINsingle Ordering data, Wiring diagrams Active import measurement, Direct connected, 1 phase, Class B (Cl. 1), Verified and approved according MID, IEC approval Direct connected electricity meter 1 phase meter 65A, Class B (Cl. 1) Order code Type Voltage IR port (V) 2CMA131040R1000 OD1065 1 x 220-240 V Yes Pulse Weight output kg No 0.135 Pulse Weight Direct connected electricity meter 1 phase meter 65A, Class B (Cl.
ODINsingle Technical data Single phase meter, direct connection up to 65A Types OD 1065 and OD 1365 Voltage (V) Nominal voltage AC Voltage range 1 x 220 - 240 -20% to +15% of nominal voltage Current (A) Imin Itr Iref (Ib) In Imax Ist 0.25 0.5 5 65 20 mA General data Frequency (Hz) Frequency range Accuracy Class Power consumption current circuits at 230 VAC and Iref Power consumption voltage curcuits 50/60 ± 5% B (Cl. 1) 0.004 VA, 0.004 W 1.0 VA, 1.
DELTAsingle Product brief Key applications Communication • Billing applications • Applications in Commercial buildings • Application in industry • Pulse output • IR port for Serial Communication Adapter • Object metering Installation Meter performance • 4 DIN modules width • • • • • • • • Terminal according to DIN 43857 (”Utility terminal”) Single phase Direct connected up to 80 A Active energy Accuracy class B (Cl.
DELTAsingle Description The DELTAsingle is a single phase meter for installation on a DIN rail in distribution boards and small enclosures such as consumer units. The meter measures active energy. The product supports a wide temperature range which makes it suitable for installation in many applications. Configuration The configuration of DELTAsingle is simple. The two buttons scroll and set are used to configure date, time and M-Bus primary address. The set button is under a sealable cover.
DELTAsingle Ordering data, Wiring diagrams Active import measurement, Direct connected, 1 phase, Class B (Cl. 1), Verified and approved according MID, IEC approval Direct connected electricity meter 1 phase meter 80A, Class B (Cl. 1) Order code *) Type Voltage No. of (V) tariffs IR port Pulse Weight output kg 2CMA180892R1000 FBB 11200 1 x 220-240 V - Yes Yes 0.150 2CMA180894R1000 FBB 11205 1 x 220-240 V 2*) Yes Yes 0.
DELTAsingle Technical data Single phase meter, direct connection up to 80A Type FBx Voltage (V) Nominal voltage AC Voltage range 1 x 220 - 240 -20% to +15% of norminal voltage Current (A) Imin Itr Iref (Ib) In Imax Ist 0.5 1.0 10 General data Frequency (Hz) Frequency range Accuracy Class Power consumption current circuits at 230 VAC and Iref Power consumption voltage curcuits 50/60 ± 5% B (Cl. 1) 0.02 VA, 0.02 W 1.3 VA, 1.
ODIN Product brief Key applications Installation • Applications in Commercial buildings • 6 DIN modules width • Object metering • Wide temperature range • Easy configuration of transformer ratio Meter performance • 3 phase • Direct connected up to 65 A Approvals • Transformer connected 5 A • MID type approval “annex B” • Active energy • MID initial verification “annex D” • Accuracy class A (Cl.
ODIN Description The ODIN is a basic meter for installation in three phase 4-wire networks. The meter is mounted on a DIN rail and is suitable for installation in distribution boards and small encloses such as consumer units. The meter is available in two versions, one direct connected and one transformer connected. Both these versions measures active energy.
ODIN Ordering data, Wiring diagrams Active import measurement, 3 phase, Class A (Cl. 2), IEC approval Direct connected electricity meter 3 phase meter 65A, Class A (Cl. 2) Order code 2CMA131024R1000 Type OD4165 Voltage No. of (V) tariffs 3 x 230/400 V IR port - Yes Voltage No. of IR port (V) tariffs Pulse Weight output kg Yes 0.393 Pulse Weight CTVT connected electricity meter 3 phase meter 10A, Class A (Cl.
ODIN Technical data Three phase meter, direct connection up to 65A Type OD4165 Type OD4110 Voltage (V) Nominal voltage AC Voltage range 3 x 230/400 -20% to +15% of norminal voltage Current (A) Imin Itr Iref (Ib) In Imax Ist General data Frequency (Hz) Frequency range Accuracy Class Power consumption current circuits at 230 VAC and Iref Power consumption voltage curcuits 50/60 ± 5% A (Cl. 2) 0.004 VA, 0.004 W per phase 0.9 VA, 0.
DELTAplus Product brief Key applications Meter performance Communication • Billing applications • 3 phase and single phase • Pulse output • Applications in Commercial buildings • Direct connected up to 80 A • • Transformer connected 1, 2 or 5 A Built-in M-Bus or LonWorks FTT 10-A interfaces • Application in Industry • Active or active and reactive energy • • Object metering • Accuracy class B or A (Cl .1 or Cl.
DELTAplus Description Tariffs The DELTAplus range includes meters for 2 and 4 tariffs. The tariffs are controlled via inputs or via communication.
DELTAplus Ordering data Active import measurement, 1 phase, Class B (Cl.1), Verified and approved according MID, IEC approval CTVT connected electricity meter 1 phase meter 6A Order code Type Voltage (V) Accuracy No. of Class tariffs IR port Pulse Weight output kg 2CMA180819R1000 DAB 11000 1 x 57-288 V B (Cl. 1) - Yes Yes 0.291 2CMA139006R1000 DAB 11001 1 x 57-288 V B (Cl. 1) 2 1) Yes Yes 0.305 2CMA139464R1000 DAB 11002 1 x 57-288 V B (Cl. 1) 4 2) Yes Yes 0.
DELTAplus Ordering data Active import measurement, 1 phase, Class B or A (Cl. 1 or Cl. 2), Verified and approved according MID, IEC approval Direct connected electricity meter 1 phase meter 80A Order code Type Voltage (V) Accuracy No. of Class tariffs IR port Pulse Weight output kg 0.308 2CMA180805R1000 DBB 11000 1 x 57-288 V B (Cl. 1) - Yes Yes 2CMA180818R1000 DBB 11001 1 x 57-288 V B (Cl. 1) 2 1) Yes Yes 0.322 2CMA180804R1000 DBB 21000 1 x 57-288 V A (Cl. 2 - Yes Yes 0.
DELTAplus Ordering data Active import measurement, 3 phase, Class B (Cl. 1), Verified and approved according MID, IEC approval CTVT connected electricity meter 3 phase meter 6A Order code Type Voltage (V) Accuracy No of Class tariffs IR port output Pulse Yes Yes Option Weight kg 2CMA180807R1000 DAB 12000 3 x 100-500 V B (Cl. 1) - 2CMA139366R1000 DAB 12001 3 x 100-500 V B (Cl. 1) 2 Yes Yes - 0.325 2CMA180806R1000 DAB 13000 3 x 57-288/100-500 V B (Cl. 1) - Yes Yes - 0.
DELTAplus Ordering data Active and reactive import measurement, 3 phase, Class B Cl. 1), Verified and approved according MID, IEC approval CTVT connected electricity meter 3 phase meter 6A Order code Type Voltage (V) Accuracy No. of Class tariffs IR port Pulse Weight output kg Yes 0.311 2CMA180809R1000 DCB 12000 3 x 100-500 V B (Cl. 1) - Yes 2CMA139453R1000 DCB 12001 3 x 100-500 V B (Cl. 1) 2 1) Yes Yes 0.325 2CMA180808R1000 DCB 13000 3 x 57-288/100-500 V B (Cl.
DELTAplus Ordering data Active import measurement, 3 phase, Class B or A (Cl. 1 or Cl. 2), Verified and approved according MID, IEC approval Direct connected electricity meter 3 phase meter, 80A Order code Type Voltage (V) 2CMA180803R1000 DBB 12000 3 x 100-500 V Accuracy No. of Class tariffs B (Cl. 1) - IR port Pulse Weight output kg Yes Yes 0.350 2CMA180801R1000 DBB 13000 3 x 57-288/100-500 V B (Cl. 1) - Yes Yes 0.374 2CMA180812R1000 DBB 13001 3 x 57-288/100-500 V B (Cl.
DELTAplus Ordering data Active and reactiv import measurement, 3 phase, Class B or A (Cl. 1 or Cl. 2), Verified and approved according MID, IEC approval Direct connected electricity meter 3 phase meter, 80A Order code Type Voltage (V) Accuracy No. of Class tariffs IR port Pulse Weight output kg 2CMA139438R1000 DDB 12000 3 x 100-500 V B (Cl. 1) - Yes Yes 0.350 2CMA139455R1000 DDB 12001 3 x 100-500 V B (Cl. 1) 2 1) Yes Yes 0.
DELTAplus Wiring diagrams Transformer connected Three phase system Three phase sytem One phase system • With neutral conductor, 4 wire (DAB13XXX) • Without neutral conductor, 3 wire (DAB12XXX) • With neutral conductor (DAB11XXX) Pulse output. External power supply up to 247 V AC or DC Pulse output. External power supply up to 247 V AC or DC Tariff input.
DELTAplus Technical data Three phase meter, direct connection up to 80A Types DBx and DDx Voltage (V) Nominal voltage AC Voltage range Types DAx and DCx 3 x 57-288/100-500 (4-wire) 3 x 100-500 (3-wire) 1 x 57-288 (single phase) -20% to +15% of nominal voltage Current (A) Imin Itr Iref (Ib) In Imax Ist 0.25 0.01 0.50 0.005 5 - - 1.
DELTAmax Product brief Key applications • Wide voltage range (100 – 500 V AC) Communication • Billing applications • LCD with 7 digits (7 mm digits) • Pulse output • Applications in Commercial buildings • Optional 2 or 4 tariffs • Built-in M-Bus interface • Application in Industry • Tariff control via internal clock • • Object metering • Previous values (daily or monthly) IR port for Serial Communication Adapter • Load profile (15, 30 or 60 min interval) Meter performance • Ma
DELTAmax Description Tariffs The DELTAmax range includes meters for 2 and 4 tariffs. The tariffs are controlled via internal clock or via communication.
DELTAmax Special features - RTC, PV, LP, MD, log and THD DELTAmax has an internal clock that handles a number of time dependent functions such as load profile, maximum demand, previous values, event and quality log, time controlled outputs and tariffs. The data from these functions are only readable via serial communication. When all available memory for a time dependent function is used, the oldest data record for that function will be over-written.
DELTAmax Ordering data Active import and export measurement, 3 phase, Class B (Cl. 1), Verified and approved according MID, IEC approval CTVT connected electricity meter 3 phase meter, 6A Order code Type Voltage (V) Accuracy No. of Class tariffs IR port Pulse Weight output kg 2CMA139495R1000 DEB 13005 3x57-288/100-500V B (Cl. 1) 2 Yes Yes 0.338 2CMA139496R1000 DEB 13006 3x57-288/100-500V B (Cl. 1) 41) Yes Yes 0.338 2CMA139497R1000 DEB 13007 3x57-288/100-500V B (Cl.
DELTAmax Ordering data Active and reactive import and export measurement, 3 phase, Class B (Cl. 1), Verified and approved according MID, IEC approval CTVT connected electricity meter 3 phase meter, 6A Order code Type Voltage (V) Accuracy No. of Class tariffs IR port Pulse Weight output kg 2CMA139509R1000 DGB 13005 3x57-288/100-500V B (Cl. 1) 2 Yes Yes 0.338 2CMA139510R1000 DGB 13006 3x57-288/100-500V B (Cl. 1) 41) Yes Yes 0.
DELTAmax Technical data Three phase meter, direct connection up to 80A Types DFx and DHx Voltage (V) Nominal voltage AC Voltage range Types DEx and DGx 3 x 57-288/100-500 (4-wire) 3 x 100-500 (3-wire) 1 x 57-288 (single phase) -20% to +15% of nominal voltage Current (A) Imin Itr Iref (Ib) In Imax Ist 0.25 0.50 5 - 80 20 mA 0.01 0.05 1.
DELTAplus/max Generic information - wiring diagram, pulse frequence Inputs or Outputs The meter is available with various input and output as options. The input can be used as an alarm or as a pulse counter, e.g., for a water meter. The output can be used as ON and OFF function, for example to switch off the current by remote control. The inputs/outputs are of opto-switch type and are galvanic isolated from other electronics parts in the meter.
DELTAmax Generic information - Time dependent functions Internal clock and time dependant functions DELTAmax meter has an internal clock that keeps track of the date and time and is equipped with various time dependant functions such as load profile, maximum demand, previous values, event log, outputs controlled by time and in tariffs. The tariffs are normally controlled via the internal clock (no external time switch required).
Communication adapters Description SCA Two-wire M-Bus The M-Bus adapter can be ordered for two-wire M-Bus usage. To connect the M-Bus loop, terminals 1-2 or 3-4 can be used. The loop continues on the other two free terminals. The M-Bus two-wire connection is polarity insensitive. The twowire connection is mainly used when several M-Bus slaves are to be connected into a M-Bus loop. The adapter is powered directly by the M-Bus and does not require an additional power source.
Communication adapters Description 100-240 VAC 1 2 3 4 SCA Ethernet M-Bus The Ethernet adapter is used for communication over Ethernet networks. The data is communicated using M-Bus over UDP or TCP. The adapter also has built in web server. The web server can be accessed through a standard web browser in a PC using the IP address of the adapter. The Ethernet adapter is powered by 100 – 240 VAC (-20/+15%) between terminal 1 and 4. To connect to an Ethernet network a RJ-45 connector is used.
Communication adapters Ordering data Serial Communication Adapter enables serial data communication between the elctricity meter and data management systems. Communication adapter, M-Bus over Ethernet Order code 2CMA137121R1000 Type CEM 05100 Voltage IR port Weight (V) output kg 100-240 V Yes Communication adapter, M-Bus over GSM/GPRS Order code 2CMA137104R1000 Type CGM 05000 Voltage IR port (V) output kg Yes 0.105 Voltage IR port Weight (V) output kg Yes 0.
Accessories Ordering data Accessories for electricity energy meters. DIN-rail Order code Type Type of electricity Application Weight meter kg 2CMA132540R1000 DIN-rail DELTAplus Wall mounting 0.025 2CMA139501R1000 DIN-rail DELTAsingle Wall mounting 0.025 Type Type of electricity Application Weight Wall mounting 0.070 Sealing 0.025 Application Weight Panel mounting 0.200 Application Weight Wall mounting 0.
Measuring Instruments Directive (MID) information Getting to terms with the MID Type approval and initial verification via NMi The Measuring Instruments Directive (MID) is a relatively new term. MID was introduced by the European Commission in 2004 to promote the free trade of measuring instruments and provide common rules for their use. As European Directive 2004/22/EC, MID came fully into force on October 30th, 2006.
Dimensions ODINsingle, ODIN ODINsingle Bottom view, terminal area Front view Side view 57.4 44 N L1 63.4 85 35.8 45 35.8 L1 Ø 4.4 38 63.4 ODIN Bottom view, terminal area Front view Side view Ø 5.3 Ø 7.4 17.5 57.4 44 85 Ø 4.4 105 Terminal area, transformer connected meter 45 35.8 63.
Dimensions DELTAsingle, DELTAplus, DELTAmax DELTAsingle Bottom view, terminal area Front view Side view SET 95 SCROLL 18 Ø7 23 72 DELTAplus/DELTAmax Side view, all meters Front view, all meters 57.1 42.4 2 35.8 96 100 45 63.
Dimensions Serial communication adapter Serial communication adapter Top view, terminal area Front view Side view 58 44 90 35.8 45 63.
Cross reference Meter type - Order code Type Order code CEM 05100 CGM 05000 CMM 05000 CRM 04000 CTM 04000 DAB 11000 DAB 11001 DAB 11002 DAB 12000 DAB 12001 2CMA137121R1000 2CMA137104R1000 2CMA137120R1000 2CMA137091R1000 2CMA137090R1000 2CMA180819R1000 2CMA139006R1000 2CMA139464R1000 2CMA180807R1000 2CMA139366R1000 DAB 13000 DAB 13001 DAB 13002 DAB 13004 DAB 13050 DAL 11070 DAL 12000 DAL 12070 DAL 13000 DAL 13001 Page Type Order code 44 44 44 44 44 26 26 26 28 28 DBM 23050 DBM 23070 DCB 11000 DCB
Cross reference Order code - Meter type Order code Type 2CDG110083R0011 2CMA131022R1000 2CMA131024R1000 2CMA131025R1000 2CMA131026R1000 2CMA131040R1000 2CMA131041R1000 2CMA132540R1000 2CMA132633R1000 2CMA132635R1000 ZS/S 1.
ABB AB Cewe-Control Box 1005 SE-611 29 NYKÖPING, Sweden Telephone +46 155 29 50 00 Telefax +46 155 28 81 10 www.abb.com Copyright 2010, All rights reserved. Specification subject to change without notice.