Installation Manual
Technical data
52
Required torque 0.5 Nm
Parameter Specifications
Strip length 5 mm
Terminal connections
•
PE/Shield: Contact input terminal 1
or 2
•
Configuration input: Contact input
terminal 2 or 1
Wire AWG and cross section: based on a copper wire type
10.12.5
Dry contacts output
The dry contacts input is the single contact in the EVSE.
Parameter Specifications
EVSE connector type Terminal block plug and screws
Wire size for the terminal block plug (al-
lowed maximum)
Wire size for the terminal block plug
(recommended)
•
2.5 - 0.5 mm
2
(Europe)
•
12 - 30 AWG (North America)
20 AWG (0.75 mm
2
) minimum
Required torque 0.5 Nm
Strip length 5 mm
Terminal connections
• Configuration output dry contact 1:
Contact output terminal 1
•
Configuration output dry contact 2:
Contact output terminal 2
Contact rated load
125 VAC/30VDC at 3A
The wire AWG and cross section are based on a copper wire type.
10.12.6
EV charge cable specifications
Parameter Value [m]
Length 8
10.13 AC output specifications
10.13.1
AC output specifications
Parameter Specification
AC output voltage range 240 V AC (1 phase)
Connection standard Type 1 cable according to SAE J1772