Installation Manual
Technical data
50
10.11
General logic interface specifications
Parameter Specification
Connectivity Mobile communication with Nano-SIM
socket type M2M (Machine To Machine)
•
2G (GSM)
•
3G (WCDMA)
•
4G (LTE)
Smart meter communication
Modbus RTU (RS485)
Modus TCP/IP
Ethernet
1x 10/100 BaseT, RJ45 Socket
Extra ethernet (daisy chain)
1x 10/100 BaseT, RJ45 Socket
WiFi (WAN) IEEE 802.11 b/g/n, 2.4 GHz
Bluetooth BLE 5.0
RFID MIFARE ISO/IEC 14443A RFID cards
Compatible mobile device operating sys-
tems
•
Android 4.4 or higher
•
iOS8 or higher
10.12
Cable specifications
10.12.1
AC input cable
Parameter Specification
EV charger station connection type Terminal /lugs and screws
Wire size for the terminal (PE) 8 AWG
Wire size for the terminal (
L1,L2)
2 AWG
Strip length 14 mm(L1,L2)/8.5mm(PE)
Cable shielding (optional) The local rules require shielded cables.
The cable shielding must be connected
to the PE rail at the two ends of the ca-
ble.
Diameter of the phase conductors Refer to the local rules.
Diameter of the PE conductor The same as te diameter of the phase
conductors
•
Consult your local electrical codes for the correct wire size, based on the envi-
ronment, the conductor type and the rating of the EVSE.
•
The wire AWG is based on the copper wire type.