Installation Manual
Technical data
44
10.3
Ambient condition
s
Parameter Value
Operation temperature -30°C
4
to +55°C
Storage temperature -40°C to +85°C
Storage conditions Indoor, dry
Relative humidity <95%, non-condensing
10.4
Mass
EVSE type Weight [kg]
Terra AC wallbox, Type 1 (North
America, Terra AC Wx-Px-xxxxx)
12.7(80A)
10.5
Protective device compliance
10.5.1
Protective device compliance (North America, Terra AC Wx-Px-
xxxxx)
Requirements Specifications
Dedicated upstream protection de-
vice(s)
Breaker
EVSE internal Ground Fault Protection 20 mA AC
Upstream overcurrent protection break-
er
Note: The breaker value de-
pends on the diameter and
the length of the cable, the
EVSE rating, and the environ-
mental parameters (for the
electrician to decide).
The breaker serves as the main discon-
nect switch to the EVSE.
Breaker rating:
•
100A for a 80 A rated EVSE
4
Based on manufacturer test result