Installation Manual
Mechanical installation
29
6
Mechanical installation
6.1
General mechanical installation procedure
Note: The mounting screws and plugs that are included in the
delivery are serviceable for a brick wall. If you want to mount
the EVSE on a different type of wall, contact your local
representative of the manufacturer (ABB EV Infrastructure).
1. Prepare the holes for the mounting screws. Refer to section 6.2.
2. Move the socket. Refer to section 6.3.
3. Install the EVSE on the site. Refer to section 6.4.
6.2
Prepare the holes for the mounting screws
Preliminary requirements
•
Spirit level
•
Drill
•
I
nstallation template.
Refer to section 10.6.
•
Plugs for the mounting
holes. Refer to section
10.6
Procedure
1. Hold the installation template
(A) against the wall.
2. Make sure that the installation is
level. Use the spirit level.
3. Mark the location for the
mounting holes (B).
4. Drill the mounting holes (B).
Note: For the diameter of
the holes, refer to the
plugs for the upper and
lower mounting holes.
5. Insert the plugs for the
mounting holes (C) in the
mounting holes.
A
B
D
E
C