Multiple MedWeld 3-Phase Systems
W2TP – Cascade Three-Phase Control
A
single MedWeld module (W) can interface
to multiple Three-Phase assemblies (TP).
In this drawing, we are showing one
MedWeld module controlling in cascade,
two Three-Phase assemblies hence
“W2TP”.
The cascade configuration time-shares one
MedWeld 3005 control for each three-phase
assembly.
4WTP – Multiple Three-Phase Control
A single enclosure can host multiple MedWeld
modules each controlling one Three-Phase
assembly. The illustration shows a multiple of
four hence “4WTP”. You may select multiples
of two and three as well.
2W4TP – Multiple Cascade Three-Phase
This illustration shows two MedWeld modules
each interfaced to two Three-Phase
assemblies for a total of four TP hence
“2W4TP”.
Four TP add up to twelve SCRs. This
configuration is available in the MedWeld
3095 enclosure in the 1200-ampere range