Specifications

MedWeld 3000 Catalog Revision 8
July 2002 Page 39 of 72
Model Number Review for Cascade Systems
The model of the above configuration can be as follows:
3095-3W9C=1200-xxxx-…..
This means that this cascade system has 3 resistance-welding processor modules (-3W)
and 9 SCRs in total (9C=1200).
Part numbers are used to classify a product in a detailed manner. There are distinct
bills of materials that are associated to a part number hence if you want to reorder an
identical system to one that has been purchased before; you would specify a “Part
Number”.
Model numbers are descriptive numbers of a general nature. It is used to classify a
product at a glance. Let’s discuss the differences between Integrated Multi Controls,
Integrated Remote Single Phase Cascade, and Integrated Multi Controls with Cascade.
Integrated Multi Control: 3075-6=1200-4003-1=#5-4806
This is a multi welder equipped with 6 resistance-welding modules, 6 SCRs (1200
amps), a 400 amp 3 pole breaker, and a size #5 isolation contactor wired for 480 volts
60 Hz. 3-phase
Integrated or Remote Single Phase Cascade: 3055-6C=1200-4002-1=#5-4806
This can be a remote enclosure equipped with one resistance-welding module
(shipped loose for installation in AB rack), or an integrated system that has one
resistance-welding module in a rack within the enclosure. There are also 6 SCRs
(1200 amps), a 400 amp 2-pole breaker, and a size #5 isolation contactor wired for
480 volts 60 Hz. Single phase.
Integrated Multi Control with Cascade: 3075-3W6C=1200-4003-1=#5-4806
This is a multi welder equipped with 3 resistance-welding modules, 6 SCRs (1200
amps), a 400 amp 3-pole breaker, a size #5 isolation contactor wired for 480 volts 60