MedWeld 3065
Model No. 3065-x=1200-xxxx-…. (Allen-Bradley ® SLC 500)
Base includes
Nema 12, Type 5 Enclosure
One MedWeld 3005 WCU module
One 1200 amp SCR
One Firing Card
One Current Monitoring Coil
Options:
Maximum: 6 SCRs – Cascade or Multi-timer
Maximum:
Two 13-slot racks with AB modules (non-interconnected)
Two 10-slot racks with AB modules (interconnected)
250 / 500 / 1000 VA Valve Power Supply & Fusing
Power lugs or Circuit Breaker
(250/400/600/800/1200/1600/2000 amp) *
Isolation Contactor (sizes 4 or 5)
SCR options: 1200 / 1750 / 2500 / 3300 amp
Options: HHT Port Kit & I/O Connectors Installed
The maximum rack size stated assumes the assumes the
use of a 400 amp Circuit Breaker
MedWeld 3065 English Metric
Approximate Weight 300 lbs 135 Kg
Dimensions 60H x 37.38W x 16D (in) 1524H x 950W x 406D (mm)
Mounting Centers 31.38W x 61.12H (in) 797W x 1553H (mm)