User`s manual

User’s Manual Version 1.3
Airolinx Wireless Serial-Ethernet Server
STW-601C
- 9 -
3.4. Hardware Installation Procedures
Prepare necessary cables, hub, power cord and RS-232/RS-485 connector.
Place STW to the area that an access point can cover, or connect it via Ethernet cable with RJ45
connector.
Connect STW’s serial port to a serial server; make sure the connector of RS-232 or RS-485 is correct.
Plug in STW to DC-9-30V power source (Or to a 9~30V DC Terminal Block, the buzzer will beep and
the RUN LED will blink if STW’s functions normally. LED Status sees
Appendix A.4.
Use monitor.exe configuration utility on the product CD to check the status of STW. If it starts up
successfully, one shall find the IP and MAC addresses of STW. One may change IP address, gateway
IP address and subnet mask networking parameters of STW to join your LAN.
Note: If there are more than one access points, the access point’s SSID shall the same.
3.5. Default Settings
The STW default settings are shown in the following table:
Property Default Value
Ethernet Port
IP Address 10.0.50.100
Gateway 10.0.0.254
Subnet Mask 255.255.0.0
WLAN Port
IP Address 192.168.1.100
Gateway 192.168.1.254
Subnet Mask 255.255.255.0
Security
User Name admin
Password Null(Leave it blank)
Serial
COM 9600,None, 8, 1, No flow control, buffer disabled, packet delimiter timer 1ms
Link Mode Type: TCP Server, Listen port 4660, Filter=0.0.0.0, Virtual COM disabled
SNMP
SysName of SNMP name
SysLocation of SNMP location
SysContact of SNMP contact
NOTE: Press reset button for 5 seconds to the default settings.