Use and Care Manual
19
TROUBLESHOOTING
WARNING: Alwaysdisconnecttheplugfromthepoweroutletbeforetroublehooting.
SYMPTON POSSIBLECAUSES REMEDY
Vacuumdoesnot
operate
Nopowertomotor
‐Plugintopoweroutlet
‐ Check power supply for blown
breakers/fuses – replace if
needed.
‐Callcustomerservicehelpline.
Dustescaping
1.Pre‐filternotinstalled 1.Installthepre‐filter
2.Holesortornpre‐filter 2.Replacethepre‐filter
3.Pre‐filtergasketnot
layingflushoncanistertop
edge
3.Checkandreinstallthe
pre‐filter.
4.Motorhousingnot
seatedorsecured
4.Reinstallmotorhousing.Or,
lockdownbothclamps.
Metal nozzle, hose or
canisterbecomeHOT
Ashistoowarmorhot
Allowashtocoolbefore
vacuuming
Reducedornosuction
1. Clogged nozzle, hose or
vacuumport
1.Checkforblockage&remove
2.Canisterfull 2.Emptycanister
3.Filterscloggedwithfine
dust
3.Cleanfiltersorreplacewitha
newfilter.
Nozzleclogseasily
Vacuumingtoomuchashat
once
Red & use manual's "Usage Hint"
section.