The Camera Body
case,
th
e beamplitter may be retracted. Remo
ve
the beamspliuer
access cap on the
battery side
of
the camera and position the
bcamsplitter by rotating the adjusunent
sc
rew approximately 30
tums counter-clockwise until
il
reaches i
ts
stop. 8ack offIhe
stop one tum
clocl.:wise.
8 - Locate two
al
l
en
head screws on the CCD head
(A
) identified
by a
red dot. Loosen the screws
1/2
a tum. While looking
al
the
monitor, gently move the CCD head until the viewing sereen
image is
in
focus. Notice that thls adjustment also affects image
rotation. When
sharp and even focus is achieved and
th
e image
is
sq
uare to the monitor, tighlen the IWO screws .
...--
_
-----,
9
-lfthe
CCD image
is
centered
in
the monitor, your adjustment
is co
mp
lete. However,
if
the image
is
off ta one side, the beam-
s
pl
i
tt.er
axis adjusunent needs to be reset. Follow the directions
under 14.4
Th
e B
eams
plitter Axis A
dju
s
tm
ent
to
recentcr the
image. Afterwards, loosen the two
screws on the CCD head and
refocus the opties.
JO
- Locate the iris rod on
th
e CCD head
(B
) and move
il
by hand
ta an upright position. Replace the eco cover on the body: take
care to locate the iris control fork and position it around the iris
lever. Tighlen the four screws to secure the caver
in
place.
Operate the manual
iri
s lever and check that the
eCD
iris itself
is
functioning by looking
al
the monitor.
lf
the brightness
of
the
image does not change, the iris
rod may nol be engaged
in
the
control fork.
Ifthi
s
is
the case, rernove the
eCD
coyer and
repeat the procedure.