7 Alarm Operation
The parameters described in this chapter are set in the WinPDM/CPDM3. See the handset’s
Configuration Manual.
Note: The alarm functionality is applicable for DT423/DT433 only.
7.1 Push-Button Alarm
The push-button can be defined to send an alarm by a long press and by multiple press.
By default, long press is defined for test alarm (see 7.1.1 Test Alarm), and multiple press is
defined for personal alarm (see 7.1.2 Personal Alarm).
7.1.1 Test Alarm
Press and hold the push-button until a dialog window "Test Alarm" (default) is
displayed. Depending on set parameters;
a beep is heard
the orange LED flashes twice
the vibrator stirs
the handset receives a notification that the alarm has been received by the system. This is a
system dependent feature.
if configured, the ALS (see 7.5 Acoustic Location Signal on page 38) is activated after the
alarm has been sent, or a call is established to a pre-defined number (see 7.6 Automatic Call
after Alarm on page 39)
information about the handset’s location is sent along with the alarm, see 7.3 Alarm with
Location Information on page 38.
7.1.2 Personal Alarm
Press the push-button twice or more, the dialog window "Personal Alarm" (default) is
displayed. Depending on set parameters;
a beep is heard
the orange LED flashes twice
the vibrator stirs
the handset receives a notification that the alarm has been received by the system. This is a
system dependent feature.
if configured, the ALS (see 7.5 Acoustic Location Signal on page 38) is activated after the
alarm has been sent, or a call is established to a pre-defined number (see 7.6 Automatic Call
after Alarm on page 39)
information about the handset’s location is sent along with an alarm, see 7.3 Alarm with
Location Information on page 38.
7.2 Man-Down and No-Movement Alarm
Man-down alarm: If the handset is tilted 45 degrees
6
or more for a preset time (default 7
seconds), the Man-down alarm will be triggered.
No-movement alarm: If no movement is detected during a preset time (default 30 seconds), the
No-movement alarm will be triggered.
6.The accuracy is -/+10 degrees.