Specifications

AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000
Page 444 01/2011 Maintenance
SHEET E-14STANDARD REPLACEMENT OF AN AXS12 MAIN CABINET
AVAILABILITY
No mission capable
1 operator on site
DURATION
15 minutes
1 Facom AZXR 15*75 Torx screwdriver for M4 screw (cover).
INGRÉDIENT(S)/CONSOMMABLE(S)
•N/A
Table 21:
OPERATION DETAILS OF THE OPERATION / COMMENTS
Back up the customer
configuration.
Precautionary operation to be carried out if there is no existing
copy (which is the case when previous installation operations
have been carried out and the procedures followed).
Refer to [1]
In the case of remote operation, contact the remote operator
before starting any operation.
Power off the iPBX. Refer to Section 6.4, Stopping the system (AXD, AXL, AXS,
AXS12 and AXS6)Error! No bookmark name given.
Nota : It is advisable to stop the IPS card before powering off the
iPBX.
Disconnect the cables. Disconnect the mains cable.
Disconnect the external cables from the front panel of the UCV
card, and mark the cables for refitting.
Remove the cover from
the old cabinet.
Unscrew the two securing screws of the upper cover, at the back
of the cabinet.
Remove the upper cover by sliding it backwards.
Remove the old cabinet.
Remove the expansion
cards.
Unlock the cards (see Figure 4.1 ) and pull them out from the
backplane.
Recover the i-button
module.
Recover, on the UCV card, the i-button module containing the
system's identifier.
Remove the cover from
the new cabinet.
Unscrew the two securing screws at the back of the cabinet,
Slide the iPBX cover to the back.
Install the i-Button
module.
Install the i-button module from the old UCV card on the new
card.