Replacing a non-duplicated RUCV-D CPU card
Table 15:
OPERATION DETAILS OF THE OPERATION / COMMENTS
Back up the customer
configuration.
Precautionary operation to be carried out if there is no existing
copy (which is the case when previous installation operations
have been carried out and the procedures followed).
Refer to [1]
In the case of remote operation, contact the remote operator
before starting any operation.
Pull out the faulty card
from its slot.
Use the 1/4 turn locks to remove the card from its slot
(see Figure 4.1 ).
Nota : The RUCV-D card can be removed from an
operational AXD iPBX.
Nota : When the active RUCV-D card fails, there is loss of
communication with the sets and lines associated
with the cards installed in the expansion cabinet.
Check that the functional
technical state of the new
card is compatible with
the old one.
.
Check the configuration of
the card.
For a card with micro-switches, check that these latter are
configured as they were on the old card, unless the configuration
has been changed (in which case, see Section 4.5).
As the card may have daughter cards, check that it is fitted in the
same way as the previous one, unless its configuration has been
modified due to a change in its capacity (in which case, see
Section 4.5 and/or the product “Data sheet”).
Insert the new card into its
slot.
Slide the card along the card guides until it clicks into place.
Lock the card in place using the 1/4 turn locks (see Figure 4.1 ).
Nota : The RUCV-D card can be hot-plugged in an
operational AXD iPBX.
Perform a software check. Check the software release of the card on the AMP (see
document [1]).
Contact your distributor if the details do not coincide.
Check the RUCV-D card
indicators.
For a card fitted with indicators, check that the yellow and/or green
indicators on the front panel are on, and that no red indicator is on
(refer to Section4.5 to check that the operating conditions indicated
by the LEDs are correct).
Activate the RUCV-D card
from the AMP.
Refer to the document [1].
Back up the customer