Specifications
Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN
Maintenance 01/2011 Page 427
• Check the
configuration of the
card.
• For a card with micro-switches, check that these latter are configured as they
were on the old card, unless the configuration has been changed (in which
case, see Section 4.3).
• As the card may have daughter cards, check that it is fitted in the same way
as the previous one, unless its configuration has been modified due to a
change in its capacity (in which case, see Section 4.3 and/or the product
“Data sheet”).
• Insert the new card
into its slot.
• Slide the card along the card guides until it clicks into place.
• Lock the card in place using the 1/4 turn locks (see Figure 4.1 ).
• Perform the wiring
exactly as in the old
cabinet.
• Power on the iPBX. • For an iPBX with several cabinets, first power on the expansion cabinet(s) by
setting the “I/O” switch of the power supply module to position “I”.
• Set the “I/O” switch on the main cabinet power supply module to position “I”.
• Perform a software
check.
• Check the software release of the card on the
AMP (see document [1]).
• Contact your distributor if the details do not coincide.
• Check the status of
the indicators on the
front panel.
Refer to Section 4, Description des sous-ensemblesError! No bookmark name
given.
• Back up the
customer
configuration.
Table 13: