Specifications
AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000
Page 426 01/2011 Maintenance
SHEET E-8REPLACING A UCV-D CPU CARD
AVAILABILITY
• Disabled if UCV-D is not duplicated
• Full mission capable if UCV-D card is duplicated
OPERATORS (s)
• 1 operator on site
DURATION
• 2 minutes
INGRÉDIENT(S)/CONSOMMABLE(S)
•N/A
Replacing a non-duplicated UCV-D card
Table 13:
OPERATION DETAILS OF THE OPERATION / COMMENTS
•Back up the
customer
configuration.
• Precautionary operation to be carried out if there is no existing copy (which is
the case when previous installation operations have been carried out and the
procedures followed).
• Refer to [1]
• In the case of remote operation, contact the remote operator before starting
any operation.
• Power off the iPBX. • Refer to Section 6.4, Stopping the system (AXD, AXL, AXS, AXS12 and
AXS6).Error! No bookmark name given. For a system with several cabinets,
first power off the main cabinet, then the expansion cabinet(s).
Nota : (1) All the system’s services are interrupted when a non-
duplicated UCV-D card is being replaced.
(2) It is advisable to stop the IPS card before powering off the
iPBX.
• Disconnect the
cables.
• Disconnect the external cables from the card and mark the cables for refitting.
• Pull out the card
from its slot.
• Use the 1/4 turn locks to remove the card from its slot (see Figure 4.1 ).
•Check that the
functional technical
state of the new card
is compatible with
the old one.