Specifications
Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN
Maintenance 01/2011 Page 423
SHEET E-7REPLACING FUSES IN THE POWER SUPPLY MODULE (AXL AND AXS
IPBX)
AVAILABILITY
• No mission capable
• 1 operator on site
DURATION
• 5 minutes
•1 multimeter
INGRÉDIENT(S)/CONSOMMABLE(S)
•N/A
Table 11:
OPERATION DETAILS OF THE OPERATION / COMMENTS
• Alert the operator. • In the case of remote operation, contact the remote operator
before starting any operation.
• Power off the cabinet's
power supply module.
• Refer to Section 6.4, Stopping the system (AXD, AXL, AXS,
AXS12 and AXS6)Error! No bookmark name given.
• If it is an iPBX with multiple cabinets, power off the power supply
module of the main cabinet then those of the expansion cabinets
("I/O" switch to "O").
• Disconnect the cables. • Disconnect the mains cable, and if appropriate the backup
battery connector:
- on the front panel of the power supply module (AXL)
- at the back of the cabinet (AXS and AXS12).