Specifications

Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN
Maintenance 01/2011 Page 417
SHEET E-4REPLACING AN AXS12/AXS6 POWER SUPPLY MODULE
AVAILABILITY
No mission capable
1 operator on site
DURATION
20 minutes
1 standard tool case
1Facom AZXR 15*75 Torx screwdriver for M4 screw (cover)
INGRÉDIENT(S)/CONSOMMABLE(S)
•N/A.
See Figure 3.16 for a view of the AXS iPBX.
Table 6:
OPERATION DETAILS OF THE OPERATION / COMMENTS
Alert the operator. In the case of remote operation, contact the remote operator
before starting any operation.
Power off the power
supply module to be
removed.
Refer to Section 6.4, Stopping the system (AXD, AXL, AXS,
AXS12 and AXS6)Error! No bookmark name given.
Disconnect the external
cables.
Disconnect the mains cable, and if required the backup battery
connected on the rear panel of the cabinet.
Remove the cabinet
cover.
Unscrew the two securing screws at the back of the cabinet,
Slide the iPBX cover to the back.
Remove the expansion
cards.
Use the 1/4 turn locks to remove the card from its slot
(see Figure 4.1 ).
Remove the guide rails.
Remove the backplane Disconnect the backplane from the main card.
Disconnect the power
supply cable from the
CPU card.
Unscrew the two securing
screws on the mains unit.
Disconnect the fan cable
from the power supply.
Pull out the power supply
module.
Unscrew the power supply module and pull it out slowly.