Specifications

AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000
Page 414 01/2011 Maintenance
SHEET E-3REPLACING AN AXS POWER SUPPLY MODULE
AVAILABILITY
No mission capable
1 operator on site
DURATION
20 minutes
1 standard tool case
1 Facom AZXR 15*75 Torx screwdriver for M4 screw (cover)
INGRÉDIENT(S)/CONSOMMABLE(S)
•N/A.
Table 3:
OPERATION DETAILS OF THE OPERATION / COMMENTS
Alert the operator. In the case of remote operation, contact the remote operator
before starting any operation.
Power off the power
supply module to be
removed.
Refer to Section 6.4, Stopping the system (AXD, AXL, AXS,
AXS12 and AXS6)Error! No bookmark name given.
If it is the power supply module of a main cabinet in an iPBX with
multiple cabinets, also power off the power supply module of the
expansion cabinets ("I/O" switch on "O").
Disconnect the external
cables.
Disconnect the mains cable, and if required the backup battery
connector on the rear panel of the cabinet.
Remove the cabinet
cover.
Unscrew the securing screws at the back of the cabinet.
Slide the iPBX cover to the back.
Remove the expansion
cards.
Use the 1/4 turn locks to remove the card from its slot
(see Figure 4.1 ).
Remove the guide rails.
If required, disconnect the
expansion ribbon cable.
If the iPBX has two cabinets, disconnect the expansion ribbon
cable linking the back plane to the expansion cable connector.
Remove the backplane Disconnect the backplane from the main card.
Disconnect the power
supply ribbon cable from
the CPU card.