Specifications

Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN
Installation and activation 01/2011 Page 359
6.3.6.1 Adding EIP cards for AXD configuration
6.3.6.1.1 Simplex AXD configuration
CONTRAINTE
This configuration implies stopping the system.
The configuration data needs to be changed if the system is expanded. Before adding
new components, first back up the data.
Immediately after installing and programming any new components, you should make
a second backup, to save the system's new configuration.
Procedure
Back up the configuration.
Power off the iPBX.
Remove the UCV card on which you will be installing the daughter card.
Install the EIP cards on the appropriate connectors. Installing a daughter card on a
card requires the use of spacers. The daughter cards are screwed onto the cards.
Re-insert the UCV card fitted with EIP cards.
Power on the system (expansion cabinets first then the main cabinet).
See Aastra Management Portal operating manual for the different phases.
Declare the network parameters of the EIP cards.
Nota : The internal IP address of the IP cards must be declared on the same sub-
network as that of the CPU card.
Activate the EIP cards.
Check the status of the EIP indicators on the front panel (see Sections 4.3 to 4.14).
Connect the EIP cards to the network.
Save the configuration.