Installation manual

IM2803MG.DOC., DIR. 912802 IM2803 Shadin Avionics
INSTALLATION MANUAL
D
IGIDATA
Rev: M
P/N 912802-A, 912802-03A, 912802-03A-G
Page: 9-2
Table of Configuration Selections
Airdata Page Options Configuration Selections
(USED/REM Pushbuttons used to select option)
Left K-Factor (in ppg) Refer to Table 1 or fuel flow transducer data sheet.
Left Offset Refer to Table 1 or fuel flow transducer data sheet.
Right K-Factor (in ppg) Refer to Table 1 or fuel flow transducer data sheet.
Right Offset Refer to Table 1 or fuel flow transducer data sheet.
Fuel Units 1. Gallons
2. Liters
3. Pounds 5.8
4. Pounds 6.7
5. Kilogram
6. Pounds 6.5
7. Pounds 6.3
Engine Type 1. Single 2. Twin
Fuel Filter Type 1. Normal (Injector) 2. Carburetor
Loran Input Type 1. Trimble
2. Arnav
3. Bendix
4. Garmin
5. Northstar
6. Foster
7. IIMorrow
8. FlowMeter
Loran Output Type 1. Format Z
2. Format X
3. Generic
4. Surveyor
5. Bendix C
6. Bendix D
7. Shadin S
8. Bendix B
9. Garmin G
Serial Communication Baud Rate 1. 9600 baud
2. 1200 baud
3. 2400 baud
4. 4800 baud
SSEC/PSEC Corrections Refer to Table 2
Endurance Warning Time 1. 45 minutes
2. 10 minutes
3. 15 minutes
4. 20 minutes
5. 25 minutes
6. 30 minutes
7. 35 minutes
8. 40 minutes
Low Fuel Warning (in fuel units) Select desired value when value is displayed.
Barometric Preference 1. In Hg 2. Millibars
OAT Temperature Probe Types 1. Shadin=0
2. Rosemount 1
3. Rosemount 2
Fuel Flow Delay Time 1. 0 seconds
2. 5 seconds
3. 10 seconds
4. 15 seconds
5. 20 seconds
6. 25 seconds
7. 30 seconds
8. 35 seconds
9. 40 seconds
10. 45 seconds
ARINC Output Status Options 1. NCD status 2. OK status
FULL Switch → Rotate to OAT Correction Code Option
Rotate to PSSEC/SSEC Option ADD Switch ←
OAT Correction Codes Refer to Shadin OAT correction code marked on package.
Set A, B, and C to those codes when selection prompt is
displayed.