Installation manual

IM2803MG.DOC., DIR. 912802 IM2803 Shadin Avionics
INSTALLATION MANUAL
D
IGIDATA
Rev: M
P/N 912802-A, 912802-03A, 912802-03A-G
Page: 5-1
5.0 INSTALLATION PROCEDURE
5.1 General
All work must conform to AC43.13-1B or later.
5.2 DigiData Panel Location Selection
The DigiData should be panel mounted in a dry, temperature stable location with enough distance
from motors, pulse generating equipment, relays and cables carrying high DC or AC current.
It may be installed in a non-pressurized and non-controlled temperature location. In considering
the location, keep in mind that the DigiData requires signals from the fuel flow, the OAT probe,
heading system (Arinc 407) and the pitot and static lines.
Remember to provide ample space behind the DigiData for the mating connectors and pitot and
static lines.
5.3 Mounting the DigiData
Depending on the DigiData part number mount per Drawing 4005-483 and 4005-479, 4005-546
and 4005-548 or 4028-A23 and 4028-A24 found in section 10. Make sure that the DigiData is not
the lowest point in the pitot and static system, to reduce the chances of collecting moisture or
water in it. Form a water trap, if necessary.