System information

FCD 901 48
Issue R2A, 07.2009
XMP1 Release 5.5 System Description
Configuration
Page 2-52 Proprietary Information Aastra
2.6.2.5 Configuration
The following section describes the setting options offered by the central
and decentral card slot data of the modules for an "Expanded Digital
Conference".
Settings in the central and decentral card slot data are possible for the
following modules (with DIX-ASIC):
DSK modular MDG
DSK modular MDV
DIX QD2ZT add-on
Note: The following settings has to be done for the E1 interfaces
which are involved in an „Expanded Digital Conference:
Info no. 3: „Disconnect also at Ext.-D & Ext.-Dk“ must be
activated.
Otherwise on the E1 interface the signal (user data) in forward
direction would be involved in the signal of the backward direction
if an on-sided error appears.
Thereby no usable transmission of the conference would be
possible.
Info no. 2: „Disconnect immediately when fault“ should be
activated. Otherwise the rebuild of the conference starts after 4 to
5 seconds.
Central card slot data
Tab. 2.K: Central card slot data for EDC
Info no. Designation Default setting
21 Exp. dig. conf. active (Dec 27-29) yes=1 0
22 Exp. dig. conf. div.: 8=0 2*4(1-4/5-8)=1 0
23 Exp. dig. conf: Master/Slave=0 equal=1 0
24 Exp. Dig. conf: root depends on C/RTSyes=1 0
26 Digital conference - converter 2 yes=1 0
27 Digital conference - converter 3 yes=1 0
28 Digital conference - converter 4 yes=1 0
29 Digital conference - converter 5 yes=1 0
30 Digital conference - converter 6 yes=1 0
31 Digital conference - converter 7 yes=1 0
32 Digital conference - converter 8 yes=1 0