System information
FCD 901 48
Issue R2A, 07.2009
XMP1 Release 5.5 System Description
Planning Values - Power Supply/Thermal Loss
Page 9-42 Proprietary Information Aastra
VEX * DSK V24/V28ext 3.0 - - - - 0.3 -
V35 * DSK V.35 4.0 - - - - 0.4 -
ISDN CHANNEL MODULES
S0F S0F (4) with FSP 8.0 - - - 0.42 0.25 -
UQF
UK0 (Q) (4) with
FSP
10.0 - - - 0.4 0.6 -
UP0 * without FSP 2.0 - - - - 0.4 -
UPF * with FSP 5.0 - - - 0.2 0.4 -
S0 * without FSP 2.0 - - - - 0.4 -
S0F * S0 with FSP 5.0 - - - 0.2 0.4 -
UKQ * UK0 (Q) 5.0 - - - 0.2 0.4 -
UKT * UK0 (T) 5.0 - - - 0.2 0.4 -
MISCELLANEOUS
SIG
Signal
concentrator
3.3 - - - 0.1 0.3 -
EA Exp. signalling 3.3 - - - 0.1 0.3 -
DIX
DIX QD2ZT
add-on
- ---- --
QD2 * QD2 adapter 2.8 - - - - 0.4 -
VIDEO MODULES
Video encoder VIE 7.3 0.12 0.01 0.02
Video decoder VID 5.9 0.1 0.01 0.02
SHDSL MODULES
ISHDSL SHD 8.7 0.16 0.19
RPS-XMP1 RMS
Table 9.P: Planning values for power supply and thermal loss of modules
SHORT
DESIGNATION
MODULE TYPE
THERMAL
LOSS
IN WATT
POWER SOURCE/ A POWER SINK / A
–UB + 7 V –8 V –UB + 7 V –8 V