System information

FCD 901 48
Issue R2A, 07.2009
XMP1 Release 5.5 System Description
Planning Values - Power Supply/Thermal Loss
Aastra Proprietary Information Page 9-41
6/8 +
6/8 KZU
TELEBRAS
5.5 - - - - 0.35 0.35
2WR *
2WR KZU
TELEBRAS
6.0 - - - - 0.4 0.4
E&M * E&M KZU 4.6 - - - - 0.25 0.35
FEK * FEK KZU 5.5 - - - - 0.35 0.35
SUB *
SUB KZU
subscriber
14.0 - - - 0.2 0.35 0.15
EX * EX KZU exchange 4.0 - - - - 0.25 0.05
OB *
OB KZU local
battery
6.0 - - - 0.1 0.3 0.1
DR2 * DR2 KZU EB5 11.0 - - - 0.2 0.3 0.1
DR4 * DR4 KZU 5.5 - - - - 0.35 0.35
ATZ * ATZ FEK 5.5 - - - - 0.35 0.35
ADPCM * ADPCM 5.5 - - - - 0.35 0.35
DSK CHANNEL MODULES
MDG
Mod. DSK G703,
worst case
5.0 - - - - 0.7 -
-
DSK modular
w/o modules
1.0 - - - - 0.1 -
-
Module G703
codir.
0.5 - - - - 0.06 -
-
Module G703
contra
1.0 - - - - 0.15 -
MDV
Mod. DSK V24
V35 V11 WT,
worst case
8.2 - - - - 1.1 -
-
Mod. DSK Vx
w/o modules
1.0 - - - - 0.10 -
- Module V.11 1.0 - - - - 0.15 -
- Module V.24 0.7 - - - - 0.08 -
- Module V.35 1.8 - - - - 0.25 -
- Module WT 1.8 - - - - 0.05 -
64k * DSK 64kb/s cod. 5.0 - - - - 0.4 0.1
V24 * DSK V24/V28 4.0 - - - - 0.4 -
X21 * DSK X21/V11 3.0 - - - - 0.3 -
WT *
DSK double
current
10.0 - - - 0.3 0.3 0.3
Table 9.P: Planning values for power supply and thermal loss of modules
SHORT
DESIGNATION
MODULE TYPE
THERMAL
LOSS
IN WATT
POWER SOURCE/ A POWER SINK / A
–UB + 7 V 8 V –UB + 7 V 8 V