Page 9-40 Proprietary Information Aastra
LE2 * Port LE CU (2) 2.5 - - - - 0.3 -
LE4 * Port LE CU (4) 2.5 - - - - 0.3 -
LEU * LE, unframed (4) 2.5 - - - - 0.3 -
PDK * Port DK (4) 2.5 - - - - 0.3 -
PORT MODULES 2 MBIT/S OPTICAL
LOU
Port LEOPT U + 2
opt. modules
10 - - - - 0.9 0.4
- - Port LE opt U 2.5 - - - - 0.4 0.05
-
- Module 2F (25
dB)
1.0 - - - - 0.15 -
- - Module 1F 1.0 - - - - 0.15 -
- Module 2F (39
dB)
3.0 - - - - 0.2 0.2
- Module 1F * 3.0 - - - - 0.2 0.2
LO1 * Port opt (1) 2.5 - - - - 0.2 0.2
LO2 * Port opt (2) 5.0 - - - - 0.3 0.4
PORT MODULES 34 MBIT/S
M34 MUX 34 KX 9.0 - - - - 0.7 0.55
L34 LE 34opt KX 9.0 - - - - 0.9 0.3
IF IF 2/8 to MUX34 4.0 - - - - 0.6 -
PORT NX64
N64 Port n*64 3.0 - - - - 0.9 -
LAN MODULES
LAP LAN (1) as Port 4.9 - - - - 0.48 0.19
LAP LAN (2) as Port 8 - - - - 0.72 0.37
LAU
LAN (1) as
converter
4.9 - - - - 0.48 0.19
LAU
LAN (2) as
converter
8 - - - - 0.72 0.37
KZU CHANNEL MODULES
OSX KZU OSX (4) 6 0,2 0,6 0,02
FEK FEK KZU II 5.5 - - - - 0.35 0.35
SUB SUB KZU II (8) 6.5 - - - 0.25 0.36 -
EX EX KZU II 3.2 - - - - 0.45 0.02
OBG * KZU OB party-line 8.0 - - - 0.1 0.3 0.1
Table 9.P: Planning values for power supply and thermal loss of modules
SHORT
DESIGNATION
MODULE TYPE
THERMAL
LOSS
IN WATT
POWER SOURCE/ A POWER SINK / A
–UB + 7 V –8 V –UB + 7 V –8 V