System information
FCD 901 48
Issue R2A, 07.2009
XMP1 Release 5.5 System Description
Planning Values - Power Supply/Thermal Loss
Aastra Proprietary Information Page 9-39
9.16 Planning Values - Power Supply/Thermal Loss
Legend: * withdrawn modules
Table 9.P: Planning values for power supply and thermal loss of modules
SHORT
DESIGNATION
MODULE TYPE
THERMAL
LOSS
IN WATT
POWER SOURCE/ A POWER SINK / A
–UB + 7 V –8 V –UB + 7 V –8 V
POWER SUPPLY MODULES
60V
Power supply
II
48/60 V
15.0 3.574- - -
60V *
Power supply
48/60 V
12.0 3.0 5.0 2.7 - - -
FSP * top/bottom 6.0 ---0.5--
FSo * FSP top 3.0 ---0.3--
FSu * FSP bottom 3.0 ---0.3--
24V *
Power supply
19-35 V
12.0 - 5.0 2.7 - - -
WND * Converter 19-75 V 35.0 3.0 - - - - -
CENTRAL UNITS
ZTQ QD2ZT with QD2 4.8 - - - - 1.1 0.1
ZTC
QD2ZT CC w/o
QD2
4.8 - - - - 1.1 0.1
ZTG
QD2ZT GN w/o
QD2
4.8 - - - - 1.1 0.1
ZT2 QD2ZT doubled 4.8 - - - - 1.1 0.1
ZCC * CC CrossConnect 4.0 - - - - 0.6 -
ZGN * GN basic network 4.0 - - - - 0.6 -
ZKV *
KV channel
distributor
4.0 - - - - 0.6 -
CC2 * CC doubled 4.0 - - - - 0.6 -
SCU (SDH-CORE UNIT)
SCU 17 0.28
EoSCU 23,28 0,48
EoSCU
with 2 x opt.
SDH-SFPs +
4 x opt.
Ethernet-SFPs
28 0,58
PORT MODULES 2 MBIT/S
Po2 Port HDB3 (2) 2.5 - - - - 0.3 -
Po4 Port HDB3 (4) 2.5 - - - - 0.3 -