System information

FCD 901 48
Issue R2A, 07.2009
XMP1 Release 5.5 System Description
Mounting the Modules in the XMP1 Subrack
Aastra Proprietary Information Page 8-15
Connecting cable
Carefully strip the insulation in the area of the terminal strip below the
modules (do not destroy the braided shield!).
Secure the cable in position using a cable tie. Ensure that there is a
good electrical contact between the shield and metallic comb rail.
There must be a highly conductive connection between the braided
shield and XMP1 subrack.
Connect the interface cable. The module logs on to the Central Unit of
the node.
To extract the module:
Remove the interface cable (if available). The module logs off from the
central unit of the node.
Loosen the cable tie at the comb rail and remove the cable.
Loosen the mounting screws of the locking bar and push it down.
Remove the grounding bracket (if available).
Module w/o activation switch:
Pull out the connecting cables and extract the module from the
XMP1 subrack.
Module with activation switch:
Before you pull out the module, set the activation switch to position 1.
Remove the connecting cable and pull out the module.
Push up the locking bar and secure it by means of screws.