System information
FCD 901 48
Issue R2A, 07.2009
XMP1 Release 5.5 System Description
Equipment with Modules
Page 8-6 Proprietary Information Aastra
8.2 Equipment with Modules
8.2.1 Central Units
Depending on the individual case of application, the XMP1 node must be
equipped with different Central Units. These must always be mounted in the
extreme right of the XMP1 subrack.
Thus, in XMP1 subrack (16), the Central Unit must be mounted in card slot
16 and in XMP1 subrack (8), it must be mounted in card slot 8.
Operation in a complex CC network with QD2 interface
If the XMP1 Flexible Multiplexer is operated in a complex CC network
monitored and managed by the ServiceOn Access Network Management
System, the Central Unit CC/QD2 (AN00102460) must be provided.
Operation in a complex CC network
If the XMP1 Flexible Multiplexer is operated in a complex CC network, the
Central Unit CC (AN00102461) or Central Unit CC/QD2 (AN00102460) is
required.
Operation as terminal/add-drop station in the basic network
If the XMP1 Flexible Multiplexer is operated as terminal or add-drop station
in a basic network, the Central Unit GN (AN00102462) is required.
Table 8.B: Central Units
XMP1 EQUIPPED FOR CENTRAL UNIT PART NO.
CARD
SLOTS IN
XMP1
SUBRACK
(16)
CARD
SLOTS IN
XMP1
SUBRACK
(8)
Operation in a complex
network with ServiceOn
Access
Central Unit CC/QD2
62.7040.310.00-A001
AN00102460
16 8
Operation in a complex
CC network
Central Unit CC
62.7040.320.00-A001
AN00102461
16 8
Operation as
terminal/add-drop
station in the basic
network
Central Unit GN
62.7040.330.00-A001
AN00102462
16 8
Operation as
terminal/add-drop
station in the basic
network with
ServiceOn Access
Central Unit GN/QD2
62.7040.335.00-A001
AN00239607
16 8