System information

FCD 901 48
Issue R2A, 07.2009
XMP1 Release 5.5 System Description
Connecting options
Page 7-6 Proprietary Information Aastra
ECC64 (optional)
In this operating mode, a SISA network can be set up within the XMP1
network by switching a digital 64 kbit/s conference.
The access node to SOA is configured as ECC64 Master. In this case,
another SISA-V (5) appears below the SISA-V. Up to 30 network elements
can be addressed via this SISA-V (5). The ECC64 Master function is
adjusted via the decentral card slot information of sub-address 5 of the
Central Unit.
When configuring the ECC64 Master node, the DIX module must be
provided via the software. In the ECC64 Master node, the 64 kbit/s
conference channel must be linked with sub-address 8 of the DIX module.
The SISA address area ranges from 1 to 30. The node number can be
identical with or differ from the SISA node number.
ECC64
SISA-V
XMP1 XQI
XMP1 Node 5
SISA-V
XMP1 XQI
XMP1 Node 7
SISA-V
XMP1 XQI
XMP1 Node 8
Decentral card slot data:
Sub-address 5 Central Unit -> ECC64
IP
SISA-V
XMP1 XQI
SISA-V
XMP1 Node 3
3
SISA-V
4
SISA-V
5
RS485 ECC8 ECC64
Menu code 75: "E.Addr.SISA-I Addr"
Menu code 76: "E.SISA-Conn. no."