System information

FCD 901 48
Issue R2A, 07.2009
XMP1 Release 5.5 System Description
Alarm list
Page 6-70 Proprietary Information Aastra
382 UNEQ Minor - Unequipped
410 tuLOP Critical - Loss of pointer X
411 tuAIS Critical -
TU12 pointers contains 'all
ones' sequence
X
412 MIS-SL Critical -
Mismatch of LO path
signal label, V5
413 MIS-PT Critical -
Mismatch of LO path
string, J2
414 SSF Minor - Server signal failure
415 loFERF Minor -
LO path far end receive
failure
420 LOS Critical Loss of Signal X
428 FOP Minor Failure of Protocol
429 SSF-W Minor
Server Signal Fail,
Working
430 SSF-P Minor
Server Signal Fail,
Protection
436 SSF Minor Server Signal Fail
437 Minor Auto Negotiation Failure
438 Critical
Down (Ethernet Layer
Down)
439 Critical
Down (Ethernet Port
Down)
440 Critical
LFD (Loss of Frame
Delineation)
441 Critical PLM ( Payload Mismatch)
442 Critical
TLCR (Loss of Total
Capacity Receive)
443 Critical
MIS-GID (Group ID
Mismatch)
444 Minor
PLCR (Loss of Partial
Capacity Receive)
445 Minor
LOSeq (Loss of
Sequence)
446 Critical LOM (Loss of Multiframe)
447 Minor
MND (Member Not
Deskewable)
448 Minor VC(1) Fail
449 Minor VC(2) Fail
Table 6.G: List of alarms
ALARM
NO.
SHORT
DESIG.
SEVERITY
LED ON SIGN.
PANEL AND
ALARM
CONTACT
ALARM DESCRIPTION
DEFAULT FOR
ALARM-
REROUTING