System information

FCD 901 48
Issue R2A, 07.2009
XMP1 Release 5.5 System Description
Alarm list
Aastra Proprietary Information Page 6-67
313 Timing Critical - Faulty timing source
314 Batt Minor -
Discharged RAM backup
battery
315 PS Minor -
Power supply failure on
remote devices
316 ICN Minor -
Fault in internal device
controller bus
SetCentral
330 LTI Critical -
Loss of all inbound timing
references
T0
331 LT0 Critical - T0 internal timing failure
332 T0Quality Minor -
T0 internal timing quality
alarm
333 NMR Minor - No more redundancy
334 PRe Minor - Pulling range exceeded
T4
335 LT4 Minor - T4 timing failure
336 T4Quality Minor - T4 timing quality alarm
337 NMR Minor - No more redundancy
TS
338 LTS Minor - Timing source failure
OSPI
339 LOS Critical - Loss of signal X
340 TX Fail Minor - Transmisson failure X
341
LPower
low
Minor -
Laser output power too
low
342
LPower
high
Minor -
Laser output power too
high
343
LBIAS
high
Minor - Laser bias current to high
RT
344 LOF Critical - Loss of frame X
345 SD Minor - Signal degraded
346 eBER Critical - Excessive bit error ratio
347 SSF Minor - Server signal failure
Table 6.G: List of alarms
ALARM
NO.
SHORT
DESIG.
SEVERITY
LED ON SIGN.
PANEL AND
ALARM
CONTACT
ALARM DESCRIPTION
DEFAULT FOR
ALARM-
REROUTING