System information
FCD 901 48
Issue R2A, 07.2009
XMP1 Release 5.5 System Description
Alarm list
Aastra Proprietary Information Page 6-61
020 n.T3 a Critical A and ZA (A)
Loss of ext. clock T3in
(act.)
021 RxCRec Minor A and ZA (A) Loss of Rx clock recovery
022 n.T3 i Minor B and ZA (B)
Loss of ext. clock T3in
(pass.)
023 PO NUM Minor A and ZA (A)
Too many ports in basic
network
024 CU TYP Minor A and ZA (A) Wrong Central Unit type
025 C_SLOT Critical A and ZA (A) Equipping fault
026 RAM Critical A and ZA (A) Fault in dynamic RAM
027 CO_CH Minor B and ZA (B)
Ports w/o co-ch. radio
alignment
028 ExtInp Minor Alarm - External input
For PS:
040 EQPT Critical A and ZA (A) Serious equipping fault
041 MON 7V Critical A and ZA (A) +7 V voltage monitoring
042 MON-8V Critical A and ZA (A) -8 V voltage monitoring
043 FAIL Minor A and ZA (A)
Standby power supply
defective
044 PS TYP Minor B and ZA (B) Wrong power supply type
045 FAIL Minor A and ZA (A)
Remote power supply
alarm
046 ST.Loc Minor EL Static fault location active
For Ports:
051 nc:LFS Critical A and ZA (A)
HDSL: loss of HDSL
frame/signal
X
052 nc: FH3 Critical A and ZA (A) HDSL: BER 10-3 local X
053 fc: LFS Critical A and ZA (A)
HDSL: Loss E1 frame/sig
remote
X
054 ng: LFS Critical A and ZA (A)
HDSL: Loss E1 frame/sig
local
X
055 fg: LFS Critical A and ZA (A)
HDSL: Loss of frame or
signal
X
056 fg: FH3 Critical A and ZA (A) HDSL: BER 10-3 remote X
057 fc: AIS Critical A and ZA (A) HDSL: AIS alarm remote X
058 ng: AIS Critical A and ZA (A) HDSL: AIS alarm local X
059 INT Critical A and ZA (A) Internal module fault X
Table 6.G: List of alarms
ALARM
NO.
SHORT
DESIG.
SEVERITY
LED ON SIGN.
PANEL AND
ALARM
CONTACT
ALARM DESCRIPTION
DEFAULT FOR
ALARM-
REROUTING