System information

FCD 901 48
Issue R2A, 07.2009
XMP1 Release 5.5 System Description
Network Reactions
Page 6-56 Proprietary Information Aastra
Reactions
Network reactions are configured in the "Tree View" of the SOX Network
Manager via the "Reactions" option. Normally, network reactions are
configured in the structure hierarchically below a filter or observer. If a
network reaction is defined in the structure directly below "Reactions", the
alarms will not be filtered.
The following network reactions can be configured:
Mail Reaction
Sound Reaction
Sound Reaction
Alarm Printer
Northbound Interface
Mail Reaction
An alarm is followed by an e-mail transmitted to a defined address.
Sound Reaction
With this option selected, an alarm is followed by an alarm signal generated
by the computer. Please ensure that the loudspeaker is active.
Switch Reaction
Using the "Switch Reaction" option, outputs can be applied to a certain
signal concentrator.
Alarm Printer
Using the "Alarm Printer" option, filtered alarms can be printed out.
Northbound Interface
The "Northbound Interface" options offers the possibility to transmit the
filtered alarms to a higher-order monitoring system.
Fig. 6.9 shows a possible configuration of a network reaction with a signal
concentrator.