System information
FCD 901 48
Issue R2A, 07.2009
XMP1 Release 5.5 System Description
Connection via F-interface (RS232)
Page 6-36 Proprietary Information Aastra
6.3.2.2 Connection via F-interface (RS232)
Direct access to the RS232 interface of a node
The following diagram shows how the PC (SOX) can be directly connected
to the RS232 interface (X3) of the Central Unit by means of a connecting
cable. The XMPIpDrv software required for this type of connection is
available on the PC besides the SOX software.
In the SOX, an Access Point must be configured and assigned the following
attributes:
Host name: Enter "local host".
IP port number: Enter the COM interface (COM1, COM2, COM...) of the
PC used.
Priority: No entry required.
XMPIpDrv COM settings:
Adjustment of the baud rate, parity and stop bits for the COM interface.
Note: An automatic connection setup to the network (Central
Unit 62.7040.xxx.xx) via the COM interface is not possible with all
SOX and Central Unit settings.
Examples:
— Settings on SOX: 57600bd, odd, 1 and on Central Unit: >2400bd,
odd, 1
— Settings on SOX: 19200bd, odd, 1 and on Central Unit: >2400bd,
none, 1
— Settings on SOX: 19200bd, odd, 1 and on Central Unit: 1200 or
2400bd, odd, 1
An automatic baud rate identification is possible only in the range from 4800
to 38400 Bd. The parity used may be even or odd. If a different baud rate is
required, the automatic identification function must be switched off first
(Central Unit - ABM Switch 5 (sub-address 0)). Then the required
parameters can be permanently adjusted by means of menu code 23.
RS232
-> X3
Operator
Terminal
XMP1
XMP1
XMP1
XMP1
XMP1
XMP1
LMT
SOX
RS232
-> X3
- XMPIpDrv