System information

FCD 901 48
Issue R2A, 07.2009
XMP1 Release 5.5 System Description
MSP Linear Multiplex Section Protection
Aastra Proprietary Information Page 3-21
A request received from the far end is executed either using the
protocol in compliance with ITU-T G.841 or a proprietary K1/K2
protocol. These requests are valid only in the bi-directional mode.
Requests include:
Lockout of protection
Force switch traffic to working channel
Force switch traffic to protection channel
Manual switch traffic to working channel
Manual switch traffic to protection channel
SF on operating path
SD on operating path
SF on protection path
SD on protection path
Wait to restore
Exercise
Reverse request
Do not revert
No request
Protocols for MSP switchover
Two different protocols can be used for MSP 1+1 control via K1- K2 bytes:
the ITU-T G.841 protocol and
a proprietary (accelerated) K1/K2 protocol with enhanced switchover
behaviour.