System information

FCD 901 48
Issue R2A, 07.2009
XMP1 Release 5.5 System Description
Analog conference without signalling (modem mode)
Aastra Proprietary Information Page 2-67
Configuration
The configuration of the analog conference is executed in the same way as
a normal module configuration.
1. Define the run of the analog conference (nodes, card slots, ports,
channels etc.).
2. Mount the KZU FEK (8) module(s) you want to use for the analog
conference.
Note: Since a KZU FEK (8) module used as conference module
has no front cable connections, it must be ensured that - after
mounting this module - the FRSTQ signal is tied to 0 V. For this
purpose a D-Sub connector (D-Sub F25 M3/S KPL Part no.
AN00055910) is used.
On this D-Sub connector, PIN 13 must be connected to the
connector housing. The FRSTQ is then tied to 0 V when the
FRSTQ D-Sub connector is plugged in.
This connection must be removed again before extracting the
module.
3. Mount the modules (SUB, FEK) you want to use for connecting the
conference subscribers. When using the SUB module, the SUB-SUB
operating mode must be configured.
4. At the Operator Terminal (MSP, SOX), the special "CNF Analog
Conference" module must be entered in the Node Equipment for the
card slots provided for the KZU FEK (8) module to be used as
conference module.
Note: When using the MSP, the sub-addresses must have been
previously entered.
5. Special settings are not required on the conference module. The
central and decentral card slot data of the "CNF Analog Conference"
module do not allow any settings.
Note: In case of an "Analog conference" in the "modem mode",
bit 1 of the central card slot data must be set to "1" for all CNF
modules.
6. Switch the conference channels in accordance with the defined run.
Use the "Standard" mode.