System information
FCD 901 48
Issue R2A, 07.2009
XMP1 Release 5.5 System Description
Configuration
Page 2-58 Proprietary Information Aastra
Two separate conference circuits
In the example depicted below, two separate conferences, i.e. conference
A and conference B, are configured in the network.
Conference A
Subscribers A-1 to A-6 participate in conference A. Subscriber A-6 is
connected to conference A in node 2 via port 2.
Main line
The main line of conference A is routed in channel 11 from node 1, port 1,
via node 2, port 1 and port 3, to node 3, port 1.
For setting up this main line, converters 1 and 2 of the modules are
connected to the corresponding ports in both node 1 and node 2.
Sub-line
Subscriber A-6 is routed in channel 14 from node 4 to node 2 and is
connected there to converter 3.
Conference B
Subscribers B-1 to B-5 participate in conference B.
The conference channel B (64-kbit/s) of conference B is routed from node
1, port 2, via node 2, port 1 and port 4, to node 4, port 2.